NETWORK ATTACHED STORAGE DEVICE, 2 BAY.
Other Specifications Download Specification | |
---|---|
Type Of Storage | Unified |
Usable Capacity Of Storage System | 8 TB |
Hardware Form Factor Of Unified/NAS System | NAS RU |
Type Of Drives | SATA |
RAID Available | Yes |
If Yes ,RAID Type | RAID 0, 1 |
Type Of Front End Ports | USB |
Number Of Front End Port | 1 |
Speed Of Front End Ports In Gbps | 1 Gbps |
Type Of Back End Ports | LAN AND USB |
Number Of Back End Port | 3 |
Speed Of Back End Ports In Gbps | 1 Gbps |
Number Of Controllers Available In Storage System | NA |
Supported Global Cache | No |
Total Configurable Cache Per Controller. | 64 MB |
Total No Of Drive Slots In The Storage System | 2 |
No Drive Slots Populated In The Storage System | 2 |
Capacity Of Single Drive Populated With The Storage System | 4 GB |
No Of Drive Slot Available For Scalability | NA |
No Of Snap Shot Copies | NA |
Remote Replication | No |
Synchronous Replocation Support | No |
Asynchronous Replication Support | No |
No Of Volume Supported | NA |
Three Way DR Capability | No |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | N |
Hot Spare Available | No |
If Yes ,No Of Drives Per Hot Spare | NA |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | No |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | No |
Network Switch | Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | NAN |
Hardware Form Factor Of Network Switch | NA RU |
Number Of Network Switches Provided With Storage System | NA |
Number Of Active Ports In The Network Switch | NA |
Operating System Platforms Supported | WINDOWS ALL |
Clustering Supported | No |
Deduplication | No |
Compression | No |
Operating Temp Range | -25 TO 70 Degree C |
Storage Temp Range | -25 TO 70 Degree C |
Operating Humidity (Rh) | 10 TO 90 % |
Storage Humidity (Rh) | 10 TO 90 % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | 612 |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | 12 V, 1AMP Watt |
Max Power Consumption Of System | -25 TO 70 Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 1 Year |
Type Of Clustering | N |