× All the transactions performed on 2.0 is available here. To access Market click "Home".

Keysight U1252A (Keysight)(U1252A)

` 36,000.00

  • MRP: `50000.00

Redefining feature-rich portability50,000 counts resolution on dual display0.025 basic DC voltage accuracy20 MHz frequency counter programmable square-wave generatorData logging to DMM up to 200 points and to PC software comes bundled with DMM, U1173A cable is required for connection to PCs USB portFully equipped from the startComes with complete test lead kit set, soft carrying case, data logging software, certificate of calibration and test reportCertified for safe useCAT III 1000V and CAT IV 600V overvoltage protectionCertified to CE and CSA.

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 50000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 3 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 50000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.005 %
AC Current Measurement 3 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 3 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 1 %
Frequency Measurement 300 Kilo Hertz
Frequency Measurement Accuracy 0.1 %
Capacitance Mreasurement Range .01 to 1000 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -50 to 1000 Degree C
Temperature Measurement Accuracy 2 %
Feature Of Continuity Test And Diode Test Not Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width 100
Safety Rating Category IV 600 V of IEC 61010
Overload Protection Through Fuse
Operating Temperature Range -20 to 55 degree C
Operating Humidity (RH) 0 - 90 (0C - 35C),0 - 70 (35C - 55C)
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 9 Volt Battery (Installed)
Total Voltage Of Battery 9 Volt
Standard Accessories Supplied With The Equipment TL75 test leads,AC175 Alligator Clips, Holster,9V battery (installed),80BK temperature probe
Dimensions (H X W X L) 201 X 98 X 52 mm mm x mm x
Weight 624 g gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. ISO9876
Test Report Date 2-4-2006
Name Of The Lab ISO
Warranty 3 Year

Price Dekho Price Dekho Price List in india