Redefining feature-rich portability50,000 counts resolution on dual display0.025 basic DC voltage accuracy20 MHz frequency counter programmable square-wave generatorData logging to DMM up to 200 points and to PC software comes bundled with DMM, U1173A cable is required for connection to PCs USB portFully equipped from the startComes with complete test lead kit set, soft carrying case, data logging software, certificate of calibration and test reportCertified for safe useCAT III 1000V and CAT IV 600V overvoltage protectionCertified to CE and CSA.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 50000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 2 % |
Feature Of Continuity Test And Diode Test | Not Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | -20 to 55 degree C |
Operating Humidity (RH) | 0 - 90 (0C - 35C),0 - 70 (35C - 55C) |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 9 Volt Battery (Installed) |
Total Voltage Of Battery | 9 Volt |
Standard Accessories Supplied With The Equipment | TL75 test leads,AC175 Alligator Clips, Holster,9V battery (installed),80BK temperature probe |
Dimensions (H X W X L) | 201 X 98 X 52 mm mm x mm x |
Weight | 624 g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | ISO9876 |
Test Report Date | 2-4-2006 |
Name Of The Lab | ISO |
Warranty | 3 Year |