× All the transactions performed on 2.0 is available here. To access Market click "Home".

Digital Earth Resistance Tester (Fluke)(Fluke 1621)

` 78,500.00

  • MRP: `90275.00

The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests.3-pole Fall-of-Potential earth testing for basic measurements, 2-pole resistance measurements for added versatility, Easily capture values with single-button operation, Ensure accurate measurements with automatic noise voltage detection, Hazardous voltage warning offers increased user protection, Clearly read and record data with a large, backlit display, Rugged holster and design for tough work environments, Portable size allows for easy transportation, Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting, 600 V Cat II..

  • Availability: 10,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurable Earth resistance range - Auto ranging
  • 2-pole method for resistance measurement - YES
  • 3-pole method for resistance measurement - NO
  • Number of the stakes - 3 NOS.
  • Diameter of the Stakes - .8 cm
Other Specifications Download Specification
Display Type 3 digit LCD display
Measurable Earth Resistance Range Auto ranging
2-pole Method For Resistance Measurement YES
3-pole Method For Resistance Measurement NO
4-pole Method For Resistance Measurement YES
Number Of The Stakes 3 NOS.
Material Of The Stakes Galvenised Steel
Length Of The Stakes 46 cm
Diameter Of The Stakes .8 cm
Number Of The Test Leads Test Lead-02 with Alligator Clips, Cable Reel-02 Nos. Nos.
Length Of The Test Leads Test leads- 2.0 M and Reel Cables 25 m - 1 nos and 50 m-01 no. cm cm
No. Of Test Leads With Clamps No Nos.
Length Of Test Leads With Clamps No cm
Measuring Range1 For Earth Resistance 0.15 to 20 Ohms
Measuring Range2 For Earth Resistance 200 Ohms
Measuring Range3 For Earth Resistance 2 Ohms
Measuring Range4 For Earth Resistance Na Ohms
Measuring Range5 For Earth Resistance Na Ohms
Measuring Range6 For Earth Resistance Na Ohms
Measuring Range7 For Earth Resistance Na Ohms
Measurable Earth Resistance Resolution For Range1 0.01 Ohms
Measurable Earth Resistance Resolution For Range2 0.1 Ohms
Measurable Earth Resistance Resolution For Range3 NA Ohms
Measurable Earth Resistance Resolution For Range4 NA Ohms
Measurable Earth Resistance Resolution For Range5 NA Ohms
Measurable Earth Resistance Resolution For Range6 NA Ohms
Measurable Earth Resistance Resolution For Range7 NA Ohms
Measurable Earth Resistance Accuracy For Range1 6 of measured value + 5D reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range2 6 of measured value + 5D reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range3 6 of measured value + 5D reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range4 Na ±% reading ± digits
Measurable Earth Resistance Accuracy For Range5 NA ±% reading ± digits
Measurable Earth Resistance Accuracy For Range6 NA ±% reading ± digits
Measurable Earth Resistance Accuracy For Range7 Na ±% reading ± digits
Stakeless Test(Clamp On) no
Facility To Measure Earth Voltage Not Available
If Yes,Measurable Earth Voltage Range Na Volts
If Yes,Measurable Earth Voltage Accuracy 23-24 %
Minimum Open Circuit Output Voltage NA Volts
Low Battery Indication Available
Over Range Indication Available
If Yes,Measurable Earth Voltage Resolution Na Volts
Internal Memory NA
Type Of Battery Used In The Power Supply 9
Battery Backup Time Standard Hours
Battery Charger Provided With The Meter. NA
Weight Of The Tester 850 grams
Dimensions(LXWXH) 11.3x5.4x21.6 cmXcmXcm
Provision For External SD Card No
Interface No
Operating Temperature Range -10 to 50 degree celsius
Operating Humidity Range 5-95 %
All Connecting Cables And Accessories To Be Supplied Along With The Tester. Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. User manual, Two measuring leads with alligator clips, 2 m (6 ft), 01 cable reel of 25m, 01 Cable reel of 50m, Earth Stakes-03 Nos., One battery, 9 V alkaline (LR61), One protective holster, yellow, One CD-ROM, Hard Carrying Case
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. Yes
Type Test Report No. 21454
TTC Report Date 21.05.2017
Name Of Lab Star Labs
Address Of Lab Delhi

Price Dekho Price Dekho Price List in india