Specifications----Instrument Control Built-In Touchscreen 7-Inch, 1280 800 High-Definition Color Display Android Based-Minimum Sample Volume 1 Ul-Limit Of Detection DsDNA Pedestal 2.0 Ng/L-BSA IgG Pedestal 0.06 0.03 Mg/ML-Maximum Concentration DsDNA Pedestal 27,500 Ng/L-BSA IgG Pedestal 820 400 Mg/ML-Measurement And Data Processing Time 8 Seconds-Measurement Repeatability Typical 0.002 A 1.0 Mm Path Or 1CV -Wavelength Range 190-850 Nm-Accuracy 1 Nm-Photometric Range 10 Mm Equivalent Pedestal 0-550 A-Accuracy 3 At 0.97 A, 302 Nm-Resolution Spectral Bandwidth 1.8 Nm FWHM At Hg 254 Nm-Pathlength 0.030 To 1.0 Mm Auto-Ranging-Light Source Xenon Flash Lamp-Detector 2048-Element CMOS Linear Image Sensor-Power Consumption Operating 12-18 W-Applications Support- Nucleic Acid A260, A260/A280, A260/A230 And Labeled Nucleic Acids Protein A280 And A205, Protein Pierce 660, Protein Bradford, Protein BCA, Protein Lowry, Labeled Proteins, OD600, Kinetics, UV-Vis, And Custom Methods delivery 4-8 weeks..
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | < 2 |
Type Of Detector | Photodiode |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | Available on request |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | Ambient Degree C |
Operating Humidity (RH) | Ambient % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | NA |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | NA |
Test Report No. | NA |
Test Report Date | NA |
Name Of The Lab | NA |
Warranty | 2 Year |