The CXA is todays leading low-cost tool for essential signal characterization. Its capabilities provide a solid foundation for cost effective testing in general-purpose and educational applications. N9000B-526 offers frequency range from 9KHz to 26.5GHz, less than 163dBm DANL and less than 110dBc/Hz SSB Phase Noise at 1GHz, with MULTI-TOUCH USER INTERFACE. With the X-Series, you can perform most operations in two steps or less using the streamlined multi-touch user interface. With X-Series signal analyzers, PowerSuite provides one button measurements of channel power,ACP, OBW, and more. For added flexibility, you can quickly and easily reconfigure the CXA with measurement applications that it changing testing requirements through license-key upgrades optionally. Standard 3 Year Warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent..
Other Specifications Download Specification | |
---|---|
Description Of The Item | Spectrum analyzers 26.5GHz |
Frequency Range | 9 kHz to 26.5 GHz |
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year | Yes |
Frequency Counter Resolution(min.) | 1 Hz |
Frequency Span | 0Hz(zero span),1kHz to 3GHz |
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz | Yes |
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc | Yes |
Sweep Time @span >or= 1 KHz | 2.6mS to 1000S |
Sweep Time @span = 0 Hz | 10 micro S to 2000 S |
Resolution Bandwidth (-3dB) | 10 Hz to 3 MHz in steps |
Video Bandwidth | 10Hz to 1 MHz in steps |
Amplitude : Max Input Level For Protection | +30 dBm |
Amplitude : Max Input Level For Measurement | +20 dBm |
Amplitude :level Measurement Uncertainity | <or=1 dB |
Average Noise Level Displayed | 300HzRBW,10Hz VBW: |
Markers | Normal and delta |
Trigger | Free run, video, External |
Display | TFT Colour display |
Interface | USB and LAN |
Measurement Features | CN ratio,AM,time domain power measurement,channel power measurement,Phase noise measurement,TOI,OBW |
Software For Transfer Of Screen Shot/measurement Data To PC | Yes |
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. | NA |
Frequency Range For 2port Vector Network Analyzer | 2 MHz to 3 GHz |
Frequency Resolution (CW ON) For 2port Vector Network Analyzer | NA Hz |
Return Loss For 2port Vector Network Analyzer | NA dB |
VSWR For 2port Vector Network Analyzer | NA |
Cable Loss For 2port Vector Network Analyzer | NA dB |
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB | NA |
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible | NA |
Phase Range For 2port Vector Network Analyzer | NA degree |
Phase Resolution For 2port Vector Network Analyzer | NA deg |
RF Output Port For 2port Vector Network Analyzer | Type N, female, 50Ohm |
Dynamic Range For 2port Vector Network Analyzer | NA dB |
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. | NA |
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible | NA |
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available | NA |
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared | NA |
Operating Temperature | 5 to 40 degree C & 80 RH 40 degree C |
Power Requirement | 230 +- 10 VAC, 50Hz |
Warranty | 3 years |
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works | yes |
One Set Of Operation And Maintenance Manual Shall Be Supplied | yes |
Standard Accessories Shall Be Supplied | yes |
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications | yes |
Test Report No | NTH(SR)/EL(C)/2014/465B |
Test Report Date | 28/11/2014 |
Name Of Lab | National Test House |
Address Of The Lab | NTH Taramani, Chennai |