NetApp FAS2600 45TB Usable on NL-SAS Drives. Dual controllers having 64GB cache across them. FC,ISCSI,FCoE,NFS,CIFS Protocols. scale out architecture..
Other Specifications Download Specification | |
---|---|
Type Of Storage | NAS |
Usable Capacity Of Storage System | 45 TB |
Hardware Form Factor Of Unified/NAS System | 4U RU |
Type Of Drives | NL SAS |
RAID Available | Yes |
If Yes ,RAID Type | RAID 6 |
Type Of Front End Ports | ISCSI |
Number Of Front End Port | 4 |
Speed Of Front End Ports In Gbps | 10G Gbps |
Type Of Back End Ports | SAS |
Number Of Back End Port | 4 |
Speed Of Back End Ports In Gbps | 12 Gbps |
Number Of Controllers Available In Storage System | 2 |
Supported Global Cache | Yes |
Total Configurable Cache Per Controller. | 32 GB |
Total No Of Drive Slots In The Storage System | 24 |
No Drive Slots Populated In The Storage System | 22 |
Capacity Of Single Drive Populated With The Storage System | 4TB GB |
No Of Drive Slot Available For Scalability | 144 |
No Of Snap Shot Copies | 255 |
Remote Replication | Yes |
Synchronous Replocation Support | No |
Asynchronous Replication Support | Yes |
No Of Volume Supported | 1000 |
Three Way DR Capability | No |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | NFS,CIFS,FC,ISCSI,FCoE |
Hot Spare Available | Yes |
If Yes ,No Of Drives Per Hot Spare | 02 |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | Yes |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | Yes |
Network Switch | Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | 10G |
Hardware Form Factor Of Network Switch | 1U RU |
Number Of Network Switches Provided With Storage System | 02 |
Number Of Active Ports In The Network Switch | 24 |
Operating System Platforms Supported | Windows, Linux, Unix |
Clustering Supported | Yes |
Deduplication | Yes |
Compression | Yes |
Operating Temp Range | 5 to 40 Degree C |
Storage Temp Range | 5 to 40 Degree C |
Operating Humidity (Rh) | 8 to 90 % |
Storage Humidity (Rh) | 8 to 90 % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | To be shared on user demand |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | 1219 BTU at 110V Watt |
Max Power Consumption Of System | 1697 BTU at 110V Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 5 Year |
Type Of Clustering | Host Based |