The fluke 107 is compact, easy to use tools. These are palm sized digital multimeters deliver safe, reliable measurements term after time. The fluke 107 are great products made to fit the way you work. These are the only fluke digital multimeters designed to fit in the palm of your hand and go with you no matter where job takes you..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.1 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 2.5 % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 2000 |
Operating Humidity (RH) | 10c to 30c |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 2AAA |
Total Voltage Of Battery | 3.0V |
Standard Accessories Supplied With The Equipment | Fluke 107 Palm-sized Digital Multimeter with Frequency, Diode Test Tl75 Hard Poin Test Lead Set 2 AAA Batteries (Installed) Users Manual Smart Strap |
Dimensions (H X W X L) | 142 x 69 x 28 mm x mm x |
Weight | 200g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 817806 |
Test Report Date | 21.05.2017 |
Name Of The Lab | Star Labs |
Warranty | 1 Year |