× All the transactions performed on 2.0 is available here. To access Market click "Home".

10 mhz function generator (scientech)(scientech 4061s)

` 24,200.00

  • MRP: `27000.00

Synthesized Function Generators are based on Direct Digital Synthesis technique to create stable and accurate output waveforms. They also offer linear ramp and square wave and pulse with fast rise/fall time.Generator also having built in Arbitrary waveforms to be used in various applications like Biomedical, Audio,Mathematics, etc. Front-panel operation is very user friendly. Internal Modulation makes it easy to modulatewaveforms without the need of any separate modulation source. Linear sweep is also built in, with adjustable start frequency, stop frequency and sweep rate from 1ms to 100 sec. Scientech S Series Synthesized Function Generators are ideal partner for your laboratories..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • No. of Channels - 1
  • Standard Waveforms - Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset
  • Band Width of Arbitrary Waveform Generator - 10 mHz to 5 MHz
  • Record Length of Arbitrary Waveform Generator - 16 Kilo Points
  • Amplitude Range (at 50 ohm impedance) - 10 mV to 10 V pp
Other Specifications Download Specification
Frequency Bandwidth (Sine Wave) 10 mHz to 25 MHz
No. Of Channels 1
Standard Waveforms Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset
Band Width Of Arbitrary Waveform Generator 10 mHz to 5 MHz
Sample Rate Of Arbitrary Waveform Generator 50 Mega Samples/sec
Record Length Of Arbitrary Waveform Generator 16 Kilo Points
Waveform Memory Of Arbitrary Waveform Generator 4 Waveforms
Vertical Resolution (Minimum) 12 Bits
Amplitude Range (at 50 Ohm Impedance) 10 mV to 10 V pp
Modulation AM, FM, PM, FSK, Burst, PWM
Interface USB
Display Colour
Standard Accessories (To Be Supplied) BNC to BNCand Power Cord
Power Requirements 230 V +/-10 AC, 50 Hz +/- 3
Operating Temperature Range 40 Degree C
Operating Humidity (RH) 85 %
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. (Test Reports Are To Be Furnished When Demanded By Buyer)" Yes
Test Report No. STPL/1802231
Test Report Date 18-12-2017
Name Of The Lab STPL, Indore
Warranty 3 Years

Price Dekho Price Dekho Price List in india