PowerEdge R940 Motherboard 12x Intel Xeon Gold 6130 2.1G, 16C/32T,10.4GT/S , 22M Cache, Turbo, HT 125WDDR4-2666iDRAC Group Manager, Enabled 1iDRAC,Factory Generated Password 12 CPU Heatsink 12.5 Chassis With Up To 24 Hard Drives ForSuper 2SSHIP,R940,NO,NO,APCC 114G OpenManage Placemat 1PowerEdge R940 Shipping Material 1No Quick Sync 1Dell EMC Luggage Tag For Super 2S 1Dell/EMC LCD Bezel For PowerEdge R940 12666MT/S RDIMMs 1Performance Optimized 132GB RDIMM 2666MT/S Dual Rank 4No 3rd/4th CPU 1iDRAC9,Enterprise 11.2TB 10K RPM SAS 12Gbps 512n 2.5in Hot.
Other Specifications Download Specification | |
---|---|
Processor Configuration | Intel Xeon Gold 6130 (2.10GHz/16-core/22MB/125W) |
Form Factor | Rack |
Processor Make | Intel |
Max. Number Of Sockets Available On Chipset | 4 |
Max. Number Of Sockets Populated With Processor | 4 |
No. Of Processor | 2 |
Number Of Core Per Processor | 16 |
Chipset Compatible With CPU | Intel C620 |
Motherboard (OEMcompatible With CPU) | Yes |
PCI Slots (Express Gen 3.0 Min.) | 13 |
Max Nos Of PCI Lanes | 192 |
Memory ( DDR4 RAM Min.) | 128 GB |
DDR4 RAM Upgradable Upto (Minimum) | 6144 GB |
DIMM Slots (Minumum) | 48 No. |
Hard Disk Drive Capacity | 4800 GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 10000 RPM |
RAID Controller Caches | 8000 MB |
RAID Controller | PERC H740P |
RAID Controller Ports | 8 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
Bays (min. 2 Internal Or More Hot Plug) | 24 |
USB Ports (version 2.0/3.0) | 4 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
DVD ROM (or Better) | 8x or better |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Available |
FC HBA Dual Port Card Speed | 16 |
Power Management | Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected |
Redundant Power Supply | Yes |
Redundant Fan | Yes |
Server Scalability To Be Achived Within The Box & Without Adding Nodes | Yes |
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | Worldwide Regulatory Compliance Engineering and Environmental Affairs, September 3, 2014 |
Name & Address Of Lab | Underwriters Laboratory(UL), Houston, USA |
BIS Registration No. Under CRS Of Deity | BIS Certificate No. --- CRS 2014-0291/R-41000868 |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | SPEC INTRatebase 2006 - 988, Specfprate2006 - 800 |
Declare Max. Power Consumption Of The System | 750 |
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | N/A |
Server Main Supply | 230V, 10,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 5 years |