Oxygen Concentrator OC 2 Plus Pressure swing absorption technology. Adjustable timer with LCD display. No consumables required. Alarms, Power failure, temperature, low and high pressure. Adjustable flow rate, Continuous flow of oxygen allows quiet and restful sleep to patients. Inbuilt Nebulizer..
Other Specifications Download Specification | |
---|---|
Conformity To ISO 80601-2-69:2014 Of The Medical Electrical Equipment – Part 2-69: Particular Requirements For Basic Safety And Essential Performance Of Oxygen Concentrator Equipment | Yes |
Flow Rate (Minimum) At 93% + - 3% Oxygen Purity | 96 Litres per minute |
Type | Portable |
Battery Duration (If Battery Operated Or Electrical Cum Battery Operated) | 0 Hrs |
Battery Charging (If Battery Operated Or Electrical Cum Battery Operated) | 0 Hrs |
Oxygen Outlet(s) | Single or Dual |
Outlet Pressure | 08 KPa |
Power Consumption | 240 Watt |
Operating Temperature Range | 30 degree C |
Operating Humidity Range | N/A % |
Operating Altitude Range | 1 Meters |
Type Of Operation | Continuous Flow Type |
Adjustable Air Delivery Mechanism | Yes |
Oxygen Concentration Monitor | Yes |
Oxygen Tank Capacity | 5 Ltrs |
Noise Level | 40 dB |
Continuous Flow | 2 LPM |
Digital Display | LCD |
Audio Alarm | YES |
Visual Alarm | YES |
Alert Of Technical Fault | YES |
Alert Of Wrong Battery | YES |
Alert Of Depleted Battery | YES |
Alert Of High Breath Rate | YES |
Alert Of Low Oxygen Purity | YES |
Alert Of No Breath | YES |
Alert For No Flow | YES |
Alert For Low Flow | YES |
Alert For High Flow | YES |
Alert Of Low Pressure | YES |
Alert Of High Pressure | YES |
Alert Of High Temperature | YES |
Alert For Power Failure | YES |
Alert For Service Requirement | YES |
Weight | 24 Kg |
Dimensions (Length) | 390 mm |
Dimensions (Width) | 337 mm |
Dimension (height) | 620 mm |
Flame Retardant | No |
Manufacturer Warranty Period | 1 Years |
Spare Part Availability | YES |
Comply With International Standards | YES |
Name Of International Standards | N/A |
FDA Approved | YES |
Availability Of Test Report CE Or EC Certification In Accordance With Appendix II(excluding Section 4) Of Medical Device Directive 93/42/EC & Its Amendment Or Equivalent | N/A |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | N/A |
Test Report No. | 977 |
Test Report Date | 22/10/2017 |
Name Of The Lab | ITL |
Address Of The Lab | Delhi |
Power Source | Electrical Operated |
Power Efficiency | 440 W/LPM |