megger mit410-2 1kv insulation resistance and continuity testers upto 200g ohm cat iv of en 61010-1 (megger)(mit410-2)

` 44,600.00

  • MRP: `69600.00

MEGGER MIT410-2 1KV Insulation Resistance and Continuity tester MK2 series are designed not just for Electrical and Industrial, but with an exceptionally wide range of applications from electrical installations, cable testing, motor testing, automotive, ESD, Panel building, avionics, maintenance etc. A variable range has been added to allow any intermediate voltage from 10 V to 1000 V in 1 V steps, where application specific test voltages are required that do not appear in the standard ranges. - The meter has dual digital display with test voltage from 50V to 1000V having insulation resistance range upto 200Gohms with PI and DAR Test built-in. The meter is CATIV 600 safety and IP54 rated, also provided with input impedance of 0.25Mohm - For more info please refer datasheet of OEM. Warranty one year on main instrument and accessories. Price is inclusive of GST@18percent..

  • Availability: 2 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - No
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection Live circuit indicator 30 V to 600v ACDC,50 Hz
Pass Fail Function No
Data Logging NA
Software Not Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range -10 To +55 C 90 RH At 40 C Max Degree C
Operating Humidity (RH) 90 RH At 40 C %
Power Requirements Battery Operated
Type Of Battery 6 X 1.5 V Cells Type IEC LR6 AA, MN1500, HP7, AM3 R6HP Alkaline
PC Interface Available
Standard Accessories Supplied With The Equipment Red/Black Silicone Test Leads With Probes + Clips SP5 Remote Switch Probe Owners Information CD Batteries 6 X AA Alkaline Hard Carry Case
Dimensions (H X W X L) 228 Mm X 108 Mm X 63 Mm 9.00 In X 4.25 In X 2.32 In mm x mm x
Weight 600g gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 5028
Test Report Date 09-05-2008
Name Of The Lab UKAS-UK
Warranty 1