× All the transactions performed on 2.0 is available here. To access Market click "Home".

MEGGER MIT515 5KV Insulation Resistance tester 10 k to 10 T CAT IV 600 V to 3000m (MEGGER)(MIT515)

` 278,000.00

  • MRP: `325600.00

MEGGER MIT515 5KV Insulation Resistance tester 10 k to 10 T with test modes IR, IRt, DAR, PI, SV, DD, ramp test with lock test voltage feature. Its dual case design protects the tester from drops/knocks and an inner fire retardant case, short circuit current noise rejection 3mA. Easy rotatory switch for Simple operation and large analogue/digital backlit display for multiple results, operates from battery or AC mains supply. High current, high noise immunity, Voltmeter Function, 5.5 hours logging, PC interface through USB using PowerDB software, rapid charge Li-ion Battery for long working hours with 4.5 hours backup. IP 65 rating with CAT IV 600V to 3000m safety for all applications, GUARD terminal for higher accuracy from leakage current. For more info please refer datasheet of OEM. Warranty One year on main instrument and accessories. Price is inclusive of GST@18percent..

  • Availability: 3 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 200 K Ohm to 1 T Ohm
  • Test Voltage - 250, 500, 1000, 2500 and 5000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - No
Other Specifications Download Specification
Type Portable
Measurement Range 200 K Ohm to 1 T Ohm
Test Voltage 250, 500, 1000, 2500 and 5000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection Live circuit indicator 30 V to 600v ACDC,50 Hz
Pass Fail Function No
Data Logging NA
Software Not Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 2 milliamper
Operating Temperature Range -20 C To 50 C Degree C
Operating Humidity (RH) 90 RH Non-Condensing At 40 C %
Power Requirements Battery Operated
Type Of Battery Rapid Charge Li-Ion Battery
PC Interface Available
Standard Accessories Supplied With The Equipment User Guide CD, Power Lead, 3 M Leadset X 3, Medium Insulated Clips
Dimensions (H X W X L) L 315 Mm X W 285 Mm X H 181 Mm mm x mm x
Weight 4.5 Kg gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 407
Test Report Date 14 February 2012
Name Of The Lab UKAS-UK
Warranty 1

Price Dekho Price Dekho Price List in india