× All the transactions performed on 2.0 is available here. To access Market click "Home".

1 kva online ups, backup 60 minutes (dextan)(dextan systems dover tt single phase hf ups 60 MIN UPS1)

` 23,000.00

  • MRP: `30500.00

1 KVA Online UPS Single Phase Input, Single Phase output,with SMF Batteries Backup 60 Minutes..

  • Availability: 30 In Stock
  • Min. Qty. Per Consignee: 15
  • Technology - MOSFET-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V 1 sinewave,50Hz
  • Minimum VAH - 936 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1 KVA
Technology MOSFET-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V 1 sinewave,50Hz
Backup Time 60 Minutes
Minimum VAH 936 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. R-41065579
Type Test Certificate Date 08-05-2017
Name Of Lab BIS
Address Of Lab NEW DELHI
Supply & Commissioning FREE OF COST
Warranty 2 Years

Price Dekho Price Dekho Price List in india