× All the transactions performed on 2.0 is available here. To access Market click "Home".

BHARTI IRON REMOVAL TABLE TOP POTABLE FILTER APPROVED FROM MDWS, GOI (BHARTI)(BHARTI-TT-IRF)

` 12,900.00

  • MRP: `15900.00

BHARTI IRON REMOVAL TABLE TOP POTABLE FILTER FOR HOUSE HOLD APPROVED FROM MINISTRY OF DRINKING WATER AND SANITATION DEPARTMENT, GOVERNMENT OF INDIA.

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 10
  • Prefilter Provided with Flushing Valve in the Iron Removal Unit - NO
  • Iron Removal Unit Suitable for Water Supply Equipment - Hand Pump
  • Discharge Capacity of the Iron Removal Equipment - 55 liter per hour LPH
  • Diameter of Vessel of Iron Removal Equipment - 320 MM +/-30 MM mm
  • Minimum Thickness of Vessel of Iron Removal Equipment - 0.40 MM +/- 0.07 MM mm
Other Specifications Download Specification
Iron Removal Unit Without
Prefilter Provided With Flushing Valve In The Iron Removal Unit NO
Iron Removal Unit Suitable For Water Supply Equipment Hand Pump
Discharge Capacity Of The Iron Removal Equipment 55 liter per hour LPH
Material Of Body Of Iron Removal Equipment Stainless Steel
Diameter Of Vessel Of Iron Removal Equipment 320 MM +/-30 MM mm
Height Of Vessel Of Iron Removal Equipment 810 MM +/- 50 MM mm
Number Of Iron Removal Vessel 03 FILTER Nos
Minimum Thickness Of Vessel Of Iron Removal Equipment 0.40 MM +/- 0.07 MM mm
Material Of Strainer Plate Of Iron Removal Equipment STAINLESS STEEL 202
Diameter Of Strainer Plate Of Iron Removal Equipment 310 MM +/- 20 MM mm
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment 0.40 MM +/- 0.07 MM mm
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment ONE IN EACH FILTER Nos
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment NA Nos
Material Of Strainer In Strainer Plate Of Iron Removal Equipment NA
Quantity Of Iron Removal Media In Iron Removal Vessel 5 KG +/- 1KG Kg
Quantity Of Filter Media In Iron Removal Media 4 KG +/- 1 KG Kg
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel 40
Back Wash Valve In Iron Removal Vessel By manually operated valve ( pumping is required for back wash)
The Accumulated Ferric Is Removed From The Media While Back Washing YES
Maximum Iron Content Of Inlet Water 15 ppm
Maximum Iron Content Of Outlet Water 0.3 ppm
Process By Which Iron Is Removed From Water By Iron Removal Media Our media works on oxidation process
Life Of Iron Removal Media 10 years Years
Cost Of Refilling Of Iron Removal Media 1100.00 Per KG Rupees
Life Of Iron Removal Unit 12 years Years
Protective Coating Of Iron Removal Vessel NA
Inlet Pipe Size Of Iron Removal Unit NA mm
Space Required For Installation Of Iron Removal Unit 12 INCH Square Metres
Number Of Valves In Iron Removal Unit NA Nos
Materal Of Valve Of Iron Removal Unit NA
Diameter Of The Valve In Iron Removal Unit NA mm
Pressure Gauge In Iron Removal Unit NO
Pressure Release Valve In Iron Removal Unit NO
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit NA Kg/square cm
Weight Of Iron Removal Unit 15 KG +/- 5 KG Kg
Warranty Period Of Iron Removal Unit 12 MONTHS Years
Arsenic Removal Unit Without
Discharge Capacity Of The Arsenic Removal Unit NA LPH
Arsenic Removal Unit Suitable For Water Supply Equipment Hand Pump
Material Of Arsenic Removal Vessel NA
Diameter Of Arsenic Removal Vessel NA mm
Height Of Arsenic Removal Vessel NA mm
Minimum Thickness Of Arsenic Removal Vessel NA mm
Number Of Arsenic Removal Vessel NA Nos
Material Of Strainer Plate Of Arsenic Removal Vessel NA
Diameter Of Strainer Plate Of Arsenic Removal Vessel NA mm
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel NA mm
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate NA Nos
Material Of Strainer In Arsenic Removal Strainer Plate NA
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel NA Kg
Media Used For Removal Of Arsenic From Water NA
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel NA
Maximum Arsenic Content Of Inlet Water NA ppm
Maximum Arsenic Content Of Outlet Water NA ppm
Life Of Arsenic Removal Media NA Years
Cost Of Refilling Of Arsenic Removal Media NA Rupees
Life Of Arsenic Removal Unit NA Years
Protective Coating Of Arsenic Removal Vessel NA
Inlet Pipe Size Of Arsenic Removal Unit NA mm
Space Required For Installation Of Arsenic Removal Unit NA Square Metres
Number Of Valves In Arsenic Removal Unit NA Nos
Materal Of Valve In Arsenic Removal Unit NA
Diameter Of The Valve Of Arsenic Removal Unit NA mm
Pressure Gauge In Arsenic Removal Unit NO
Pressure Release Valve In Arsenic Removal Unit NO
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit NA Kg/square cm
Weight Of Arsenic Removal Unit NA Kg
Warranty Period Of Arsenic Removal Unit NA Years
Iron Removal Media Conform To International Standard National Science Foundation, USA
Arsenic Removal Media Conform To International Standard DIN EN 15029
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate YES
Field Testing Kit For Testing Iron & Arsenic Is Provided YES

Price Dekho Price Dekho Price List in india