AUTO RANGEDisplay of maximummeasurable limitsSound AlarmUnder or over range4 lines LCD display andkeyboar d controlsLanguage optionsEnglish / French / German /Catalan / Spanish / Italian /Japanese / Polish / Dutch /PortugueseFrieNdly userUniversal adapterAll accessoriessuch as BrookfieldOptionalAUTO-TESTIt checks the internalfunction in order to makethe unit ready to useDisplayed InfoViscosity cP or mPas Torque, ResolutionUsing low viscosity adapter 0.01For lower than 10.000 viscosity cP 0.1For viscosity equal to or above 10.000 cP 1 Repeatability 0.2 Supplied at 100-240 VAC, 50/60 Hz, SpindlesAISI 316 stainless steel spindles, easily identified by number and letter whenchanged according to range of viscosity. Main Features Data displayedSelected speed r.p.mSelected spindle SPViscosity reading cP mPasPercentage of full scale Relative and absolute viscosity. Unit converter SI to CGS. AUTO-TEST with sound and visual malfunction alarm. AUTO-RANGE function. User-enable.
Other Specifications Download Specification | |
---|---|
Type | Microprocessor Based |
PH Range | 0.00 to 14.00 pH |
Resolution | 0.01 pH |
Accuracy | +- 0.05 pH |
Calibration | up to 3 points with auto buffer |
Modes | pH mV- C |
Display | LED / LCD / Touch Screen, 3 digits |
Temperature Compensation Type | Automatic |
Temperature Compensation Range | 0 to 100 Degree C |
Temperature Accuracy | +- 0.3 Degree C |
Parallel Temperature Indication | Yes |
Storage Pocket For PH Electrode | Yes |
System To Be Supplied With Measuring Electrode Combined (glass Calomel), Temperature Probe, Electrode Stand, Calibration Buffer And Maintenance Kit, Operation Manual, Power Cable And Plug. | Yes |
Ingress Protection (Water Tight) | 0 |
Impact Resistant | Yes |
Corrosion Resistant | Yes |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | yes |
Power Requirements | 230 V +- 10, 50 Hz AC |
Operating Temperature | 100-240 VAC, 50/60 Hz Degree C |
Operating Humidity (RH) | 85 % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer) | ISO: 2555, 1652 |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | 9001:2015 |
Test Report No. | 123 |
Test Report Date | 01.01.2018 |
Name Of The Lab | Fungilab Spain |
Warranty | 1 Year |