A Complete automation of the electrophoresis processes reduces operator time to a minimum.PRODUCTIVITY-The range of kits, available with various gel sizes, contributes to guaranteeing a productivity suitable for any workload, streamlining consumption.ANALYSIS PANEL-In addition to Immunofixation and Bence-Jones, the system performs serum protein, urine, haemoglobin, isoenzyme and lipoprotein electrophoresis as well as CSF isoelectric focusing.FLEXIBILITY-Automatic recognition of the analysis program and simultaneous treatment of up to two gels, even with different methods, allow a flexible use of the analyser.TRACEABILITY-Automatic reading of the test tube, gel and antiserum barcodes ensures traceability of samples and reagents.QUALITY-Maximum standardisation of the analysis processes guarantees accurate results and an easy interpretation.SYSTEM ERGONOMICS-Flexible and easy to useMaintenance reduced to a minimumIntegrated densitometer..
Other Specifications Download Specification | |
---|---|
Types Of System | Horizontal Gel Electrophoresis system |
Applications | To separate charged molecules like DNA/RNA and proteins according to the size |
Series Of Electrophoresis | Large |
No. Of Maximum Samples Which Can Run | 54 Nos |
Body Material Of Electrophoresis Unit | Metal |
Size Of Unit (WxLxH) | 21504272 mm |
Gel Tray Requirements | The tray should be UV proof and should have integrated fluorescent ruler which should get illuminated on exposure to UV lights for easy and safe calculation of the band movement |
Material Of Gel Tray | Fiber |
Width Of The Gel Tray | 10 cm |
Length Of The Gel Tray | 15 cm |
Thickness Of Combs And Colour Code | 1mm-white,1.5mm- Red,2mm-Blue |
All Combs Of Adjustable Height | Yes |
No. Of Wellcombs | 30 Nos |
Width Of Well,cm | na cm cm |
Length Of Well,cm | 5 cm |
Volume Of Gel,ml | ml kits ready to use ml |
Type Of Electrode | platinum |
The Base Buffer Volume,ml | 300 ml |
Details Of Other Components Included | na |
Required Dye Chemicals | violet stain |
Specified Voltage For Dye Migration | 200 V |
Dye Migration Rate | 4.5 cm/hr |
Maxi.output Voltage Of Power Supply Unit | 200 V |
Output Current | 0-100ma mA |
Ouput Wattage,W | 35 W |
Constant Voltage | Yes |
Constant Current | Yes |
Display | LCD display |
Control | Microprocessor controlled |
No. Of Electrode Terminal Ports | 4 Nos |
Alarm For Time Completion | Yes |
Timer Range Up To | 30 minutes |
Autostart After Power Breakdown | Yes |
Operating Voltage | 100-240v 50-60 hz V |
Operating Temperature Range | 30 deg.C |
Power Unit Dimension (LxWxH) | 21524070 mm |
Weight Of Power Unit | 35 kg |
Warranty Period Of The System | 1 years |
Details Of Consumables To Be Supplied | Titan III-H Cellulose Acetate (94 mm x 76 mm)-12 samples 3021 Titan Cellulose Acetate (76 mm x 60 mm)-8 samples 3022 Supre-Heme Buffer 5802 Hemo AFSA2 Control 5330 Hemo AA2 Control 5328 Hemo AFSC Control 5331 Hemo ASA2 Control 5329 Hemolysate Reagent 5125 Ponceau S 5526 Clear Aid 5005 Titan Blotter Pads 5034 Zip Zone Prep 5090 Titan Plastic Envelopes 5052 Helena Marker 5000 Identification Labels 5006 Zip Zone Chamber Wicks 5081 Glue Stick 5002 PermaClear |
Installation,commissioning And Training Part Of The Supply | Yes |