Keysight Technologies 33521B 30MHz Single Channel Function Generator with exclusive Trueform signal generation technology offer more capability, fidelity and flexibility than previous generation DDS generators. Easily generate the full range of signals you need to your devices with confidence the signal generator is outputting the signals you expect. Keysight 33521B-30MHz Single Channel arbitrary waveform generator offers all standard waveforms and 30MHz Pulse Generator, lowest harmonic distortion of just 0.04 percent, 8.4 - ns rise and fall time, highest amplitude resolution upto 16 bit, 1Micro Sample per second to 250 Mega Sample per second sample rate, 1M record length, 16 bit vertical resolution, USB,GPIB,LAN Interface, 4.3 inch color QVGA Display, remote operation using web user interface. Standard 3 Year Warranty. Refer Keysight datasheet for detailed specifications. Standard Delivery Period is 6 weeks. Prices indicated including GST @18 percent...
Other Specifications Download Specification | |
---|---|
Frequency Bandwidth (Sine Wave) | 10 mHz to 25 MHz |
No. Of Channels | 1 |
Standard Waveforms | Sine, Square, Pulse, Ramp, Noise, Sin(x)/x, Exponential rise/fall, Gussian, DC Offset |
Band Width Of Arbitrary Waveform Generator | 10 mHz to 25 MHz |
Sample Rate Of Arbitrary Waveform Generator | 250 Mega Samples/sec |
Record Length Of Arbitrary Waveform Generator | 128 Kilo Points |
Waveform Memory Of Arbitrary Waveform Generator | 4 Waveforms |
Vertical Resolution (Minimum) | 12 Bits |
Amplitude Range (at 50 Ohm Impedance) | 10 mV to 10 V pp |
Modulation | AM, FM, PM, FSK, Burst, PWM |
Interface | USB |
Display | Colour |
Standard Accessories (To Be Supplied) | Power Chord, USB Cable, Certificate of Calibration, Documentation CD |
Power Requirements | 230 V +/-10 AC, 50 Hz +/- 3 |
Operating Temperature Range | 0 to 55 Degree C Degree C Degree C |
Operating Humidity (RH) | 5 to 80 RH, non-condensing % |
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. (Test Reports Are To Be Furnished When Demanded By Buyer)" | Yes |
Test Report No. | NTH (SR)/EL(C)/2013/27 (B) |
Test Report Date | 04-02-2013 |
Name Of The Lab | National Test House, Taramani Chennai |
Warranty | 3 Years |