Oscilloscope.
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 1mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, Ground on Screen |
Time Base Range | 2 ns/div to 50 s/div |
Trigger Types | Edge, Pulse width, Pattern, Video, External |
Measurements | 23 Built-in Automatic Measurement,Snapshot all, maximum, minimum, peakto- peak, top, base, amplitude, overshoot, preshoot, average- N cycles, average-full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cycles, AC RMSfull screen -std dev, Period, frequency, rise time, fall time, + width, width, duty cycle, delay AB-rising edge, delay AB-falling edge, phase AB-rising edge, and phase AB-falling edge, bit rate |
Frequency Analysis Feature | No |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Peak Detect, Averaging, High Resolution |
Display Type | Colour |
Display Size | 8.5-inch WVGA with 64 levels of intensity grading CM CM CM |
I/O Interface | USB Interface Standard, LAN and VGA Optional |
Standard Accessories To Be Supplied | Four nos. of 300MHz passive probe, 10:1, Power Chord, Certificate of Calibration and Documentation CD |
Operating Temperature Range | 0 to +55 C Degree C |
Operating Humidity (RH) | Up to 80 RH at or below +40 C % |
Power Supply | 230V +- 10 , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | 1016QFL04 |
Test Report Date | 05/09/2016 |
Name Of The Lab | JAS-ANZ RAJKOT GUJARAT |
Warranty | 5 Year |
Real Time Bandwidth | 200 MHz |
Record Length Per Analog Channel Simultaneously | 100 kpts per channel (standard), 1 Mpts Optional Mega Point Mega Point Mega Point |
Sample Rate Per Analog Channel Simultaneously | NA2 GSa/s half-channel interleaved, 1 GSa/s per channel GS/sec GS/sec GS/sec |
Waveform Update Rate | 50000 Waveforms/ |
Time Base Accuracy | 25 PPM |