This is a 3KW - 230 VAC - 50 Hz Solar Power Conditioning Unit Or Solar Inverter With Inbuilt High Range MPPT Solar Charge Controller. This Is A Pure Off Grid Inverter Having Single Phase Grid Input And Single Phase Grid Output, With An Optional Battery Requirement That Means This Off Grid Solar Inverter Can Be Used With Or Without Battery Based On Requirement. During And Based On The Availability Of Solar Power This Inverter Can Work Without Grid Also. The Inverter Capacity Is 3KVA And The Power Factor Is 1 Hence The Maximum Connected Load To This Inverter Or PCU Can Be Upto 4KW And The Maximum Connected Solar Panel Would Be 4 KW..
Other Specifications Download Specification | |
---|---|
Rating Of Inverter | 3 KVA |
ISI Marked | NO |
If ISI Marked Yes, CM/L No. | NA |
Mode Of Operation | Stand-alone |
Nos. Of Phase | single |
Inverter's Output Wave Form | Pure sine wave |
Inverter Efficiency | 100 |
Switching Device | IGBT |
Total Harmonic Distortion | Less than 3 % |
Operating AC Voltage Range | 90 to 280 VAC Volts |
Operating Frequency Range | 50 to 60 Hz (Auto sensing) Hz |
Operating Temperature | - 10 Degree to 50 Degree degree cel |
Operating Relative Humidity | 99 % |
Load Power Factor | 1 |
Maximum Power Point Tracking(MPPT) | yes |
Galvanic Isolation Between Input DC & Output AC | yes |
Ingress Protection Rating Of Inverter | IP 23 for indoor use |
Built In Protection For AC High/low Voltage & Frequency If Connected To AC Mains | IP 23 for indoor use |
Output Regulation At Rated Voltage | Yes |
By-pass Facility If Connected To AC Mains | IP 23 for indoor use |
Over Load Protection 110% For 60 Seconds ,125% For 30 Seconds And 150% For 5 Seconds | yes |
Display Type | LCD |
Display Parameters Like DC Voltage(V),DC Current (A), AC Voltage (V) | YES |
Conformity Of Inverter To Environmental Testing Conditions As Per IEC 600688-2 (1,2,14,30) Or Equivalent BIS Standard | YES |
Sequence Of Power Drawing | 1. SPV 2. AC Mains( if connected with AC power) 3. Battery bank |
Nos. Of Modules In An Array | 12 NOS. |
Rating Of Individual PV Module | 325Wp / 96 Cell / HIT / 55.9 - 69.6 VDC Wp |
Efficiency Of Solar Panel | 19.4 (HIT), 18 (mSi), 17 (pSi) % |
Reverse Polarity Protection For PV Modules | yes |
90% Performance Warranty For SPV | 10 years |
80% Performance Warranty For SPV | 25 years |
Salt Mist Corrosion Resistant Material For Body & Frame Of SPV Module | Aluminium |
Area Required For Installation Of Solar Pannels With Mounting Structure | 100 sq. mt |
TTC For PV Module From Any MNRE Lab As Per MNRE 2015-2016 | yes |
Test Report Number | 21235957.003 |
Date Of Test Report | 24/11/2015 |
Name And Address Of Laboratory | TUV Rehinland LGA Products GmbH Tillystrasse 2, 90431Nurnberg, Germany |
OEM Test Report For Indigenously Produced PV Module(s) | yes |
Provision For Solar Generation Meter | yes |
Provision For Bidirectional Meter(Net Meter) | yes |
Provision Of Anti Rusting/ Non Corrosive Mounting Structure | yes |
Material Of Mounting Structure | Stainless steel |
Sustainability Of Wind Speed. | 150 KM/Hr |
Type Of Battery | Tubular Gel KM/Hr |
Battery Backup Time At Rated Load | 4 Hour |
Battery Bank Voltage | 24 Volt |
Capacity Of Battery Bank | 3600 to 4800 VAH |
3 Stage Battey Charging ( Float, Boost & Equalize Stage ) For Long Life Of The Battery | yes |
Reverse Polarity Protection | yes |
Complete Installation Work To Be Done By Supplier | yes |
Gross Weight Of The Inverter | 9 kg |
Availability Of Type Test Report For Inverter Including Environmental Tests From Central Government/NABL/ILAC Accridiated Laboratory To Prove Conformity To The Specification | yes |
Test Report Number | NTC13091899E - 1 |
Date Of Test Report | 01/06/2016 |
Name And Address Of Laboratory | Dongguan NTC Co. Ltd. Building D Gaosheng Science & Technology Park, Hongtu Road, Nancheng District, Dongguan City, Guangdong Provience, China |
Type Test Report To Be Furnished On Buyers Demand | yes |