× All the transactions performed on 2.0 is available here. To access Market click "Home".

2kva online ups (bpe)(mf1102)

` 55,750.00

  • MRP: `65800.00

High Frequency and double conversion on-line technology.Fully digitalized microprocessor control.Wide input voltage rangeHighly Efficient upto 90High input power factor 0.99LCD displayCold startIGBT both Inverter Rectifier stage.Advanced battery managementAutomatic battery charge in UPS OFF modeShort circuit overload protection.EMI/RFI noise filter.Smart RS232 communications with monitoring softwareOptinoal SNMP Card slot.High reliability digital controlFull protection function.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 5
  • Technology - IGBT-PWM without inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V 1 sinewave,50Hz
  • Minimum VAH - 4800 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 2 KVA
Technology IGBT-PWM without inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V 1 sinewave,50Hz
Backup Time 120 Minutes
Minimum VAH 4800 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer No (only for IGBT-PWM Technology)
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. R85001546
Type Test Certificate Date 13.12.2017
Name Of Lab Bureau of Indian Standards
Address Of Lab Manak Bhavan, 9 Bahadur Zafar Shah Marg New Delhi 110002
Supply & Commissioning 5
Warranty 3 Years

Price Dekho Price Dekho Price List in india