fluke 115 true--rms multimeter with 3 year warranty flukefluke 115 true--rms multimeter with 3 ye (fluke)(fluke 115 true--rms multimeter)

` 9,690.00

  • MRP: `13084.00

Display - 3.5 DigitMeasurement Type - True RMSCount - 6000AC Voltage Measurement Accuracy - 0.5 AC Current Measurement - 10 Ampere.

  • Availability: 2 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 6000
  • AC Voltage Measurement Accuracy - 0.5 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 6000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.5 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.5 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 1.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 1 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 1 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 0.1 %
Capacitance Mreasurement Range .01 to 1000 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement NA Degree C
Temperature Measurement Accuracy NA %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory NA
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width NA
Safety Rating Category II 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range -10 C to 50 C
Operating Humidity (RH) 90
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 9V Alkaline
Total Voltage Of Battery 9V
Standard Accessories Supplied With The Equipment Model includes the following: Holster Installed 9 V battery Test leads User manual
Dimensions (H X W X L) 167.1 mm X 85.1 mm X 46.0 mm mm x mm x mm x mm x
Weight 550gms gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 2704-6-03
Test Report Date 8-1-2016
Name Of The Lab Intertec Testing Services ISO 9001:2008
Warranty 3 Year