Bandwidth up to 2.5 GHz and sampling rates up to 40 GS/s make the DPO7254C a natural choice for analyzing critical, high-speed signals. Over 30 analysis packages provide in-depth measurements for communications standards, jitter analysis, memory bus standards, vector analysis and more. Plus, the Windows operating system lets you run your own analysis software right on the instruments..
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | Yes |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 1mV/Div to 1 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC,DC,GND |
Time Base Range | 1.25 ps/div to 8.19 M s/div |
Trigger Types | Edge, Glitch, Width, Runt, Window, Timeout, Transition, Setup/Hold, Pattern, State, Visual Trigger & search |
Measurements | 53 Automatic Measurements which 8 can be displayed at any one time (Amplitude, Time, Combination, Histogram, Communication related), Time & Voltage Cursors, Math (Add, Subtract, Divide, Multiply, Integration, Differentiation), Frequency Domain functions, Algebraic Expressions |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | No |
In-built Function Generator | No |
Acquisition Modes | Sample, Peak Detect, Average, Envelope, Hi resolution, Waveform database, fast frame acquisition |
Display Type | Colour |
Display Size | 30.73 CM |
I/O Interface | LAN,USB 2.0,USB 3.0, GPIB |
Standard Accessories To Be Supplied | P6139B-One passive voltage probe per analog channel (500 MHz, 10X, 8 pF), Front cover, Mouse, Power cord, Calibration certificate |
Operating Temperature Range | +5 to +45 Degree C |
Operating Humidity (RH) | 8% to 80% relative humidity (RH) % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | NYH(SR)/EL(C)/2013/325(F) |
Test Report Date | 07.10.2013 |
Name Of The Lab | NTH,Chennai |
Warranty | 3 Year |
Real Time Bandwidth | 2500 MHz |
Record Length Per Analog Channel Simultaneously | 25 Mega Point |
Sample Rate Per Analog Channel Simultaneously | 10 GS/sec |
Waveform Update Rate | >250000 Waveforms/ |
Time Base Accuracy | 2.5 PPM |