UNITY STORAGE.
Other Specifications Download Specification | |
---|---|
Type Of Storage | Unified |
Usable Capacity Of Storage System | 100 TB |
Hardware Form Factor Of Unified/NAS System | 5U RU |
Type Of Drives | NL SAS |
RAID Available | Yes |
If Yes ,RAID Type | RAID 6 |
Type Of Front End Ports | 8 X 16 Gb, 4 x10 Gb BASE T,4 X 10 Gps sfp plus |
Number Of Front End Port | 16 |
Speed Of Front End Ports In Gbps | 16 Gbs, 10 Gbps Gbps |
Type Of Back End Ports | 4 X12 Gbps SAS PORTS |
Number Of Back End Port | 4 X12 Gbps SAS PORTS |
Speed Of Back End Ports In Gbps | 4 x12 Gbps Gbps |
Number Of Controllers Available In Storage System | 27 or more |
Supported Global Cache | Yes |
Total Configurable Cache Per Controller. | 24 GB |
Total No Of Drive Slots In The Storage System | 27 or more |
No Drive Slots Populated In The Storage System | 26 |
Capacity Of Single Drive Populated With The Storage System | 6 TB NL SAS GB |
No Of Drive Slot Available For Scalability | MIN 150 OR MORE |
No Of Snap Shot Copies | 256 |
Remote Replication | Yes |
Synchronous Replocation Support | Yes |
Asynchronous Replication Support | Yes |
No Of Volume Supported | AS PER OEM |
Three Way DR Capability | Yes |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | NFS,ISCI,FC,CISF |
Hot Spare Available | Yes |
If Yes ,No Of Drives Per Hot Spare | 2 |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | Yes |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | Yes |
Network Switch | Not Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | NA |
Hardware Form Factor Of Network Switch | NA RU |
Number Of Network Switches Provided With Storage System | NA |
Number Of Active Ports In The Network Switch | NA |
Operating System Platforms Supported | REDHAT, WINDOWS, HP- UX, IBM AIX |
Clustering Supported | Yes |
Deduplication | No |
Compression | No |
Operating Temp Range | 10- 35 Degree C |
Storage Temp Range | 25 /HR Degree C |
Operating Humidity (Rh) | 20- 80 % |
Storage Humidity (Rh) | Relative humidity/ 20-80 non conduncing % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | CRS -2014-0215.R-41000140 |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | .8Kva Watt |
Max Power Consumption Of System | 1 Kva Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 3 Year |
Type Of Clustering | HOST BAESD |