Microteck 3 KVA (Microtek SS)(Microtek SS 3 KVA)

` 36,999.00

  • MRP: `44000.00

Rated Capacity 3 KVA / 2700 Watts Input Voltage Range Load 50 118 295 V 5 V Input Voltage range Load 50 160 295 V 5 V Frequency 40 70 Hz Phase Single Phase with Ground Power Factor 0.99 @ full load Output Voltage Range 208 / 220 / 230 / 240 V AC THD Linear Load 2 Efficiency 85 92 Battery Charge Current 1.5 Amps DC Voltage 72 V6 7.2 AH Battery inside.

  • Availability: 9 In Stock
  • Min. Qty. Per Consignee: 1
  • Overall Efficiency (AC-AC) (in %age) - > 87 Percentage %
  • Input Voltage And Range (in Volts) - 230V 50Hz and Range 160 Volt - 280 Volt ( Full Load) and 230 Volt 50Hz and Range 100 Volt - 280 Volt ( Half Load) Volt
  • Input Frequency Range (in Hz) - 50-60 Hz Hz
  • Input Power Factor - 0.95 or better
  • Frequency (in Hz) - 50 Hz +/- 0.1 Percentage Hz
Other Specifications Download Specification
Technology (a) IGBT based PWM Technology (b) Microprocessor controlled Digital Design (c) Double Conversion True On-line UPS (d) Manufacturer: IS9001 and IS14001 Certifiedand Small 2U height maximizes available space. Rack-mount with user replaceable battery and Add on batteries for extended back-ups
Overall Efficiency (AC-AC) (in %age) > 87 Percentage %
Input Voltage And Range (in Volts) 230V 50Hz and Range 160 Volt - 280 Volt ( Full Load) and 230 Volt 50Hz and Range 100 Volt - 280 Volt ( Half Load) Volt
Input Frequency Range (in Hz) 50-60 Hz Hz
Input Phase Single Phase with ground
Input Power Factor 0.95 or better
Output Voltage (in Volt) 220 Volt AC-230 Volt AC Volt
Voltage Regulation (in %age) +/-3 Percentage %
Frequency (in Hz) 50 Hz +/- 0.1 Percentage Hz
Harmonic Distortion (THD) < 3 Percentage (linear load) %
Output Waveform Pure Sine wave
Crest Factor 3 ratio 01
Output Power Factor 0.9 or more
Battery Backup Minimum 1 hour battery backup ( Minimum VAH 12000)
Battery Type Sealed Lead Maintenance Free VRLA type (Lead Calcium SMF batteries NOT acceptable)
DC Bus Voltage As per OEM Architecture
Transfer Time 0 milli second milli sec
Battery Enclosure MS Rack Powder Coated
Operating Temperature 0 to 40 Degree C deg.C
Noise Level <55 dB at 1 Meter dB
Alarms And Indications All necessary alarms and indications essential for performance monitoring of UPS to be incorporated.
Bypass Automatic Bypass Switch
Compatibility UPS tbe compatible with DG Set supply
Communication Interface (a)Standard RS 232 port for software interface (b)Standard SNMP interface support
Dimension In Mm (Height X Height X Width) 45.77 x 34.7 x 5.8 mm mm
Certifications IS9001 and IS14000 and EN 60950 and EN/IEC 62040-2 and cULus and CE and Federal Communications Commission
Environnemental Compliance RoHS 7b Exemption

Price Dekho Price Dekho Price List in india