× All the transactions performed on 2.0 is available here. To access Market click "Home".

20 kva online ups,pwm - igbt , isolation transformer,3Phase in 3phase out (NEXUS)(20000-III OL EB, pwm - igbt , isolation transformer,3Phase in 3phase out, without battery)

` 199,600.00

  • MRP: `2400000.00

NEXUS IS AN ISO 90012008 ,ISO 140012004 PRODUCTS CO. The UPS Is Supplied With EXIDE Make SMF Batteries For 30 Min. Backup.High Frequency PWM - IGBT Based Technology, Microprocessor Based Design- Constant Voltage Constant Frequency CVCF- Constant Voltage Constant Charger CVCC- LCD Display For UPS Status Monitoring / Built In ISOLATION TRANSFORMER For Total Isolation Between Input Output , Resulting In Absolutely Zero DC Components - Wide Input Range, Pure Sine Wave Output / Transfer From Mains To Inverter Without Break, Silent Operation Mode Noise 60dBA- Power Factor 0.8 To Unity, High Efficiency 85, THD 3 - Operating Temp. 0 500 C, Humidity 5 90 Non Condensing- Parallel Redundancy / Hot Standby Facility Optional- Multiple Cooling Fan Control,Bypass Switch Available, Static Bypass Optional / Small Foot Print / Easy Movable. UPS INPUT 3 PHASE, UPS OUTPUT 3 PHASE, DC VOLT 360V DC.

  • Availability: 3 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - Three phase 300 V - 450V sinewave,50Hz
  • Output power - 3 phase 400 V 1 with alternative user setable setting of 380V+-1,50Hz
  • Minimum VAH - 23400 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 20 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power Three phase 300 V - 450V sinewave,50Hz
Output Power 3 phase 400 V 1 with alternative user setable setting of 380V+-1,50Hz
Backup Time 30 Minutes
Minimum VAH 23400 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without trolley but with Rack
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. E-01150317
Type Test Certificate Date 03-03-2016
Name Of Lab EQUALITIES CERTIFICATION LIMITED
Address Of Lab 817,ANSALS KIRTI SHIKHAR, NEW DELHI-58
Supply & Commissioning 7
Warranty 1 Years

Price Dekho Price Dekho Price List in india