The occlusal view reveals the skeletal or pathological anatomy of either the floor of the mouth or the palate. The occlusal film, which is about three to four times the size of the film used to take a periapical or bitewing, is inserted into the mouth so as to entirely separate the maxillary and mandibular teeth, and the film is exposed either from under the chin or angled down from the top of the nose. Sometimes, it is placed in the inside of the cheek to confirm the presence of a sialolith in Stensons duct, which carries saliva from the parotid gland. The occlusal view is not included in the standard full mouth series. packet of 25 sheets size 4 57x76mm.
Other Specifications Download Specification | |
---|---|
Table Top Automatic Medical X Ray Film Processor Machine | Yes |
The Assembly Made Up Of Material Non Corrosive | Yes |
Length Of Machine | Na |
Width Of Machine | Na |
Height Of Machine | NA |
Weight (Empty) | NA |
Auto Developer , | Yes |
Auto Fixer | Yes |
Auto Washer | Yes |
Auto Dryer | Yes |
Material Of Cabinet | ABS Plastic |
Rollers Mechanism | Motrised |
Rollers Material | PVC with inner pipes of SS-304 Grade |
Minimum Film Size Length X Width | 100 x 100 |
Maximum Film Size Length X Width | 356 x 432 |
Continious Film Roller Transport And Auto Start And Stop Facility | Rigid PVC |
Processing Time: 90 Sec To 200 Sec In Steps Of Six Second With LED Display | Yes |
Processing Capacity Of Size 356mm X 432 Mm In 90 Second Mode | Yes |
Minimum Capacity Of Fixer,Washer And Developer Tank | 5 |
Mimimum Capacity Of Replenishment Developer And Fixer Tank With Overflow Drain Facility | 25 |
Automatic Replenishment | Yes |
Developer And Fixer Temprature Adjustable Throught Automatic Temprature Controller | Yes |
Operating Temp Range | (28-37 )degree degree |
Dryer Temprature(maximum) | 70 degree |
Power Supply | 230 volt A.C |
Maximum Power Consumption | 1.4 kwh |
Water Filter Compatible With Equipment Supplied With Equipment | Yes |
Manual ,auto Stop With Power Saver/standby Mode Facility | Yes |
High Voltage Test 1.5 KV For I Minute | Yes |
Minimum Insulation At 500 V DC | NA |
Instruction Manual Supplied With Equipment | NA |
Chemicals/Materail For Running Equipment For Minimum One Month | NA |
Radiology Certificate For Processed Film | Na |
Availibility Of Type Test Report For Performance Test | yes |
Test Report To Shown To Buyer As And When Required | Yes |
Test Report Number & Date | 21485 |
Name & Address Of Laboratory | Human Care Lab & Uttarakhand |
Certifiacation | CE |