APCs Back-UPS 1100 protect your electronic equipment from damage due to power outages, surges, and spikeswhile providing short term battery power during an outage. Back-UPS 800 and 1100 both feature Automatic VoltageRegulation AVR, which instantly adjusts high and low voltages to a safe level for your electronics, so you can workindefinitely through sustained fluctuations. Specifically designed to protect your equipment and network connection inharsh power environments, the Back-UPS 800 and 1100 ensure maximum productivity and work efficiency....
Other Specifications Download Specification | |
---|---|
Rating In KVA/ Min VAH Capacity Of Battery | 0.5/84 KVA/VAH |
Technology | MOSFET-PWM |
Input | Single phase sinewave(160-280v) Volt |
Rated Output | Single phase sinewave 230v AC , 50Hz Volt |
Load Power Factor | .66 |
Variation In AVR Output In AC Mode | 5 % |
Variation In Output Voltage In Battery Mode | 5 % |
Variation On Output Frequency In Battery Mode | .5 Hz |
Inverter Efficiency | 92 % |
Total Harmonic Distorsion | 30 % |
Switching Over Time | 8 Mili sec |
Overload | 10 % |
Overload Time | 10 Minutes |
Protection Against Short Circuit Of UPS | Yes |
Protection For Outside Input Voltage Range | 220 Volt |
Protection Against Discharge Per 12v Battery | 10.5 Volt |
Degree Of Protection | IP-21 |
Type Of Battery | Tubular confirming to IS:13369 |
Type Of Enclosure | Mild steel |
Dry Heat Test At 45 Degree For 16 Hrs As Per IS:9000 Pt-3/sec-5 | Yes |
Damp Heat Test At 45 Degree , RH -95% For 2-cycle As Per IS:9000 Pt-5/sec-1 | Yes |
Cold Test As Per IS:9000 Pt-2/sec-4 | Yes |
Availability Of The Type Test Report From Central Govt./NABL/ILAC Accredited Lab | Yes |
Type Test Certificate No. And Date | R-83000450 14-06-2017 |
Name Of Lab | BUREAU OF INDIAN STANDARDS |
Address Of Lab | Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi110002 |