With its unbeatable high RCF with fixed-angle rotors, th Rota 4 is at the top of its class. Extensive swing-bucket, fixed-angle as well as well- plate carriers for increased versatility and selectable speeds up to 20000 rpm or 32198xg make the Rota 4 a true all-rounder suitable for a variety of applications including blood diagnostics, medical research and cell culture laboratories, inorganic chemistry, production laboratories. The Rota 4R- Refrigerated version easily achieves 4 degree C at maximum speed..
Other Specifications Download Specification | |
---|---|
Centrifuge Design | Bench Top |
Centrifuge Type | Super Speed Centrifuge |
Speed Mode | Variable Speed |
Rotor Configuration | Fixed Angle |
Interchangeable Rotors | YES |
Material Of Rotor | Aluminium |
Finish Of Rotor | Electroplated |
Autoclavable Rotor At 121 Degree Celsius | YES |
Type Of Drive Motor | Brushless AC Motor |
Controler Type | Microprocessor Controlled |
Body Material | Metal Alloy |
Finish Of Body | Powder coated |
Base Material | Steel |
Lid Type | Opaque |
Lid Material | Steel |
Lid Lock Detector | YES |
Emergency Lid Lock Release | YES |
Automatic Braking | YES |
Number Of Sample Tubes Testable Simultaneously | 24 |
Volume Of The Tube Testable | 1.5/2 ml |
Maximum Speed | 20000 RPM |
Minimum Speed | 100 RPM |
Speed Increment Step, If Variable Speed | 100 RPM |
Speed Control Accuracy Of Set Speed (+/-) | 100 RPM |
Maximum Relative Centrifugal Force(RCF) | 32198 x g |
Calibration | Manual Calibration |
Temperature Control Method | Refrigerated |
If Refrigerated, Refrigeration System Free From CFC/HCFC | YES |
Temperature Setting Range(increment Step) | -10 to +40 Degree Celcius |
Temperature Control Accuracy Of Set Temperature(+/-) | 0.5 Degree Celcius |
Acceleration Time (full Speed) | 20 sec |
Deceleration Time( Full Stop) | 20 sec |
Number Of Acceleration/deceleration Profiles In-built | 20 |
Timer Provided | YES |
Timer Setting (Increment Step) | 99:59:59 min |
Input Method/Interface | Digital Front panel With Glove mode |
Display Option/Output Read Out Option | Digital |
Type Of Data Logging Option | NA |
Rotor Imbalance Detection | YES |
Auto Cutoff | YES |
Pulse Mode | YES |
Programmable | YES |
Number Of Storable Programmes,If Programmable | 99 |
Input Voltage With Phase | 230 V |
Power Consumption | 750 W |
Input Current | 15 A |
Noise Level (maximum) | 60 db |
Ambient Operating Temperature | 24 Degree Celcius |
IP Rating Or Ingress Protection Rating | 21 |
External Dimension: Height | 410 mm |
External Dimension: Width | 705 mm |
External Dimension: Depth | 575 mm |
Weight Including Default Rotor | 90 kg |
Accessories And Spares Included In Standard Pack | Reduction adapters |
Additional Safety Features | Active Imbance detection, user friendly operation, propreitory lid lock system, Large Back-lit LCD display panel |
Free Service Available | YES |
Warranty On Rotor And Machine | 2 Years |
Supply Of Free Spare Parts Under Warranty | YES |
Annual Maintenance Contract(AMC) Available After Warranty | YES |
AMC Contract Period | 1 Years |
Product Code Available On Supplier Website | YES |
If Yes, Product Code | Rota 4R |
Firm Certified To ISO9001:2008 Or Latest | YES |
Product Is CE Certified | NO |
If CE Certified, EN/IEC Directives | NA |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | NA |
Test Report No. | NA |
Test Report Date | NA |
Name Of The Lab | NA |
Address Of The Lab | NA |
Number Of Free Services, If Provided | 3 |