DSO 100 Mhz 2 Channels.
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 1mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, GND |
Time Base Range | 2.5 ns/div to 50 |
Trigger Types | Edge, Pulse Width, Video, Slope, Alternative |
Measurements | Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean, Crms, Vrms, ROVShoot, FOVShoot,PREShoot, , FPREShoot, Rise time, Fall time, Freq, Period,+ Wid, -Wid, +Dut, -Dut, BWid, Phase,FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF,Add, subtract, multiply, divide &1024 point FFT |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Peak Detect, Averaging, High Resolution |
Display Type | Colour |
Display Size | 13 CM |
I/O Interface | USB |
Standard Accessories To Be Supplied | Two 1X/10X Switchable Probes, Calibration Certificate , Power Cord |
Operating Temperature Range | 10-40 Degree C |
Operating Humidity (RH) | 85 % |
Power Supply | 230V +- 10 , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | 1/17-18/0887 |
Test Report Date | 10/8/17 |
Name Of The Lab | TDC |
Warranty | 1 Year |
Real Time Bandwidth | 100 MHz |
Record Length Per Analog Channel Simultaneously | 2 Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1 GS/sec |
Waveform Update Rate | 30000 Waveforms/ |
Time Base Accuracy | 100 PPM |