× All the transactions performed on 2.0 is available here. To access Market click "Home".

uniline greenline series 2 kva online ups (uniline)(gl 2000 va)

` 56,000.00

  • MRP: `69000.00

Green Lines outstanding features Pure sine wave output ECO mode to save energy Rotatable LCD display design Optional AS400 relay card 19rack mount kit available for all models Tower / Rack multi-configuration forflexible installation Microprocessor control guarantees high reliability Adopting high frequency full bridge topology for high steady performance High input power factor correction Selectable various output range and operating mode Cold start function Inbuilt static bypass enhance better protection for critical load Built-in dry contact / RS-232 / EPO communication port SNMP allows for web-based remote or monitoring management Optional USB communication port Optional Enable to extend run time with scalable external battery pack Overload, short-circuit, and over heat protection Hot-swappable battery design Compact size with high over all efficiency.

  • Availability: 25 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V 1 sinewave,50Hz
  • Minimum VAH - 2420 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 2 KVA
Technology MOSFET-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V 1 sinewave,50Hz
Backup Time 120 Minutes
Minimum VAH 2420 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 92 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. 2965
Type Test Certificate Date 27/01/2009
Name Of Lab ELECTRONICS TEST & DEVELOPMENT CENTRE
Address Of Lab G T ROAD NEAR IOC DEPOT AMBALA CANTT 133001
Supply & Commissioning UPS & Batteries shall be installed by our Engineer at site, but site shall be got prepared for Input & output electrical work by the consignee / Indentor
Warranty 2 Years

Price Dekho Price Dekho Price List in india