× All the transactions performed on 2.0 is available here. To access Market click "Home".

microplate elisa reader (sinduri)(elisa reader)

` 175,000.00

  • MRP: `245000.00

MICROPLATE ELISA READER.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Eight Lamp automatic turret with independent eight power supplies with coded lamp compatible - Yes
  • Monochromator with Wavelength range 190-900 nm. - Yes
  • Holographic grating of high density of not less than 1800 lines/mm - Yes
  • Titanium burners for Acetylene nitrous oxide (C2H2- N2O) & Acytelene-Air (C2H2-AIR) with precise Knobs for burner optimization i.e. height, rotational and lateral - Yes
  • Burner movement thorough computer, all three directional, height, rotation lateral - Yes
Other Specifications Download Specification
Computer Controlled True Double Beam Atomic Absorption Spectrophotometer Yes
Eight Lamp Automatic Turret With Independent Eight Power Supplies With Coded Lamp Compatible Yes
Monochromator With Wavelength Range 190-900 Nm. Yes
Holographic Grating Of High Density Of Not Less Than 1800 Lines/mm Yes
System Have Wavelength Locating By Automatic Peak Searching, Auto Loading Of All Parameters And Auto Bandwidth Selection And Continuously Variable Selection 0.2-2.0 Nm With D2 Lamp Background Correction Yes
Titanium Burners For Acetylene Nitrous Oxide (C2H2- N2O) & Acytelene-Air (C2H2-AIR) With Precise Knobs For Burner Optimization I.e. Height, Rotational And Lateral Yes
Fully Inert Nebulizer Yes
Gas System With Automatic Flame Changeover, Full Safety Interlock Including Pressure Sensors On Both Line, Power Failure Protection, Burner Interlock And Flame Sensor, Flame Ignition Should Be Automatic Yes
Burner Movement Thorough Computer, All Three Directional, Height, Rotation Lateral Yes
PTFE Spray Chamber And Adjustable Impact Bead Aerosol Yes
Single Element Coded Hollow Cathode Lamps : Cu, Fe, Zn, Mn, Mg B, K, Mo. Yes
System Have Facilities Of Repeat Of Result Of Same Sample And Date Treatment. Automatic Calculation Of Percentage In Base Material Yes
Standard Accessories To Be Supplied : 1. Acetylene And Nitrous Oxide Gas Cylinders Should Have Explosive Certification With Regulator 2. Two Filled Cylinders For Each Gas, 3. Air Compressor, 4. Air Filter, 5. Spares And Consumables For 2 Years Operations. 6. SS Exhaust Fume Hood With Inert Centrifugal Blower, 7. Instruction Manual 8. Circuit Diagram Yes
Spare One Set Hollow Cathode Lamps Of Cu, Fe, Zn, Mn. No
100 Ml Standard Solutions Of 1000 Ppm For Each Element Under Guarantee Certificate Yes
. Training At The Time Of Installation Up To User Level Satisfaction Yes
PC Software Available
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " CE
Power Requirements 230 V +- 10, 50 Hz
Operating Temperature 37 Degree C
Operating Humidity (RH) 5 %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" NA
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) NA
Test Report No. NA
Test Report Date NA
Name Of The Lab NA
On-site Warranty 1 Year
Availability & Supply Of Spare Parts & Accessories For next 10 years

Price Dekho Price Dekho Price List in india