IGBT Based Rectifier True Online Double Conversion with DSP Control Technology for High Performance and Reliability. New Graphical LCD DisplayProvides UPS Data, Alarms andHelps in faults diagnostics andtrouble shooting. Double Conversion Efficiency up to 90. Active Input Power Factor Correction 0.99. 0.8 Output Power Factor. Wide Input Voltage window110 - 280 Vac for Indian Environmental Condition and for Optimized Battery Performance. Configurable Output Voltage200/208/220/230/240 Vac. Generator Compatible with Wide Input Frequency Range40 Hz-70 Hz. 4 Stage Extendable Charging Design for optimized Battery Performance. Adjustable Battery Charging Current 1/2/4/6 Amps according to Battery Capacity and Rating. 50/60 Hz Automatic Frequency Converter Mode. Intelligent Monitoring with Standard RS232/USB Port Plus Slot Available for RS485/Dry.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 2 KVA |
Technology | IGBT-PWM without inbuilt isolation transformer |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V 1 sinewave,50Hz |
Backup Time | 30 Minutes |
Minimum VAH | 1872 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 3 % |
Overall Efficiency | 92 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | Without |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | SMR/TMC/09-10/emerson-03 |
Type Test Certificate Date | 26-02-2018 |
Name Of Lab | Sameer |
Address Of Lab | Mumbai |
Supply & Commissioning | yes |
Warranty | 2 Years |