Keysight MSOX2014A Mixed Signal Oscilloscope - 100MHz-4-Analog Plus 8-Digtal Channels with largest screen size of 8.5 Inches in its class, deepest memory 1Mpts and the fastest waveform update rates 200000 wfrm/s, 2GSa/s Sampling rate, built-in 3-digit digital voltmeter and Training Signals, 5-years standard warranty. FUTURE UPGRADABLE OPTIONS LIKE BUILT-IN 20 MHZ BUILT-IN FUNCTION GENERATOR WITH AM/FM/FSK MODULATION, SERIAL PROTOCOL TRIGGERING AND DECODE, MASK TESTING UPGRADE FEATURE AVAILABLE, BANDWIDTH UPGRADE UPTO 200MHz. USB Interface. MSOX2014A comes with two nos. of 150MHz 10x1 passive probe, power chord, certificate of calibration, 8-channel logic probe, documentation CD Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent. Delivery period 6 weeks...
Other Specifications Download Specification | |
---|---|
Type | Mixed Signal |
Operating System | Non -Windows |
Bandwidth Upgradability | Yes |
No. Of Analog Channels | 4 Number |
Digital Channels | Yes |
No. Of Digital Channels | 8 Number |
Record Length Per Digital Channel Simultaneously | 500 kpts per channel GS/sec |
Sampling Rate Per Digital Channel Simultaneously | 1 Gsa/s Mega Points Mega Points |
Min. Detectable Pulse Width | 5 ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 1mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, Ground on Screen |
Time Base Range | 5 ns/div to 50 s/div |
Trigger Types | Edge, Pulse width, Pattern, Video, External |
Measurements | 23 Built-in Automatic Measurement,Snapshot all, maximum, minimum, peak-to-peak, top, base, amplitude, overshoot, preshoot, average- N cycles, average-full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cycles, AC RMS- full screen -std dev, Period, frequency, rise time, fall time, + width, width, duty cycle, delay AB-rising edge, delay AB-falling edge, phase AB-rising edge, and phase AB-falling edge, bit rate |
Frequency Analysis Feature | No |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Peak Detect, Averaging, High Resolution, Segmented |
Display Type | Colour |
Display Size | 8.5-inch WVGA with 64 levels of intensity grading CM |
I/O Interface | USB Interface Standard, LAN and VGA Optional |
Standard Accessories To Be Supplied | Four nos. of 150MHz passive probe 10:1, Power Chord, Certificate of Calibration and 8 Channel Logic Probe Documentation CD. Instrument has inbuilt 3-digit Digital Voltmeter and Built-in training signals, that enable users to quickly learn to capture and analyze simple (e.g. sine wave) or complex (e.g. radar pulse) signals with controlled real-time signal generation and It includes dynamic teaching labs contains an array of built-in training signals. |
Operating Temperature Range | 0 to +55 Degree C Degree C |
Operating Humidity (RH) | Up to 80 RH at or below +40 C % |
Power Supply | 230V +- 10 , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | MSOX2014AMY57230613 |
Test Report Date | 18-AUG-2017 |
Name Of The Lab | Keysight Technologies Malaysia |
Warranty | 5 Year |
Real Time Bandwidth | 100 MHz |
Record Length Per Analog Channel Simultaneously | 1 Mpts Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1 GSa/s per channel GS/sec |
Waveform Update Rate | 200000 wfrm/s Waveforms/ |
Time Base Accuracy | 25 PPM |