The MAX-710B is the first tablet-inspired OTDR that is handy, lightweight and rugged enough for any outside plant environment.With a 7-inch, outdoor-enhanced touchscreen, the most efficient handheld display in the industry, it delivers an unprecedented user experience. Its intuitive and Windows-like GUI ensures a fast learning curve. Plus, its new and improved OTDR 2.0 environment offers icon-based functions, instant boot-up, automatic macro bend finders as well as improved auto and real-time modes. The Max-710B is a genuine last-mile OTDR from the worlds leading manufacturer. It delivers EXFOs tried and true OTDR quality and accuracy along with the best optical performance for first-time-right results, every time. It is optimized for the point-to-point testing and troubleshooting of FTTx architectures, and is ideal for testing short fibers e.g., inside a CO environment or at FTTA/DAS network installations. In addition to its amazing 12-hour battery life..
Other Specifications Download Specification | |
---|---|
Channels | Single Nos. |
Max. Clock Rate | 1310-1550nm MHz |
Max. State Data Rate (Standard) | 10/100 Mbit/s Mbps |
Timing (All Channels, All The Time) | Available |
Capacitive Loading | 30/28 db pf |
Setup/Hold Time (Adjustable) | 0.1 to 160 km Distance Range ns |
High Speed Timing/Timing Zoom(With Record Length/Sample Depth) | 0.04 to 5m Sampling Resolution GHz,ps |
Deep Memory Timing For Half Channels | 256000 Sampling Points GHz |
Deep Memory Timing For Full Channels | 4m Attenuation dead zone GHz |
Memory Depth With Timestamp For Half Channels | 2GB Internal Memory M |
Memory Depth With Timestamp For Full Channels | Memory to Store 20000 traces K |
Trigger States | 0.001 db loss resolution |
Trigger Types | 5 ns to 20 us Pulse Width |
Simultaneous State And Timing Analysis | Not-Available |
Setup/Hold Violation | Not-Available |
External Peripheral Interface | USB |
Display Type | Touchscreen, 800 x 480 TFT |
Display Size | 17.78 cms. |
Number Of Probes To Be Supplied | Standard Nos. |
Type Of Probes To Be Supplied | Built-in Battery Pack with 12 Hours Backup, AC Adapter with Power Cord, Quick Reference Guide, CD ROM with Soft copy on Unit, SC/APC Connector, Calibration Certificate, Soft Carrying Case. |
Operating Temperature | Minus 10 to 50 Degree C |
Operating Humidity (RH) | 0-95 % |
Operating Voltage | 9-16 V DCIN Volts |
Power Consumption (Max.) | 25 Watts |
Interoperability With Oscilloscope | Yes |
Availability Of Type Tests Reports From A Central Govt. Lab OR International Laboratory Accreditation Cooperation (ILAC)or Their Worldwide Affiliated/ Recognised Labs OR NABL Approved Lab Showing Conformity To The The Specifications. | Yes |
Name Of The Lab | ISO |
Address Of The Lab | ABS Quality Evaluations |
Test Report No. And Date | 49118 dated 27 Oct 2016 |
Warranty | 3 Years |