Cisco UCS Server Appliance with management license.Cisco Prime Infrastructure UCS Physical HW Appliance900GB 6Gb SAS 10K RPM SFF HDD/hot plug/drive sled mountedSFS Power Cord - 250V, 10A , IndiaCisco Prime Infrastructure 3.2 UCS Appliance Software2.30 GHz E5-2650 v3/105W 10C/25MB Cache/DDR4 2133MHz. Cisco Ent MGMT Lic For PI 3.x And APIC EM Solution AppsPrime Infrastructure 3.1 SoftwareCisco Ent MGMT PI 3.x Platform Base Lic..
Other Specifications Download Specification | |
---|---|
Processor Configuration | E5-2650 v4, 12 core, 2.20GHz with 30 MB smart cache memory, 105 watt |
Form Factor | Rack |
Processor Make | Intel |
Max. Number Of Sockets Available On Chipset | 1 |
Max. Number Of Sockets Populated With Processor | 1 |
No. Of Processor | 1 |
Number Of Core Per Processor | 10 |
Chipset Compatible With CPU | Intel C610 |
Motherboard (OEMcompatible With CPU) | Yes |
PCI Slots (Express Gen 3.0 Min.) | 2 |
Max Nos Of PCI Lanes | 2 |
Memory ( DDR4 RAM Min.) | 4x16GB DDR4-2400-MHz GB GB |
DDR4 RAM Upgradable Upto (Minimum) | 64 GB GB |
DIMM Slots (Minumum) | 4 No. No. |
Hard Disk Drive Capacity | 4X900 GB GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 10K RPM RPM RPM |
RAID Controller Caches | 1 GB MB MB |
RAID Controller | 12G SAS Modular Raid Controller |
RAID Controller Ports | 8 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
Bays (min. 2 Internal Or More Hot Plug) | 2 |
USB Ports (version 2.0/3.0) | 2 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
DVD ROM (or Better) | 8x or better |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Not-Available |
FC HBA Dual Port Card Speed | N |
Power Management | Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected |
Redundant Power Supply | Yes |
Redundant Fan | Yes |
Server Scalability To Be Achived Within The Box & Without Adding Nodes | NA |
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | R-41004530 |
Name & Address Of Lab | Vincular Testing Labs, Uttarahalli Road, Banguluru-61 |
BIS Registration No. Under CRS Of Deity | R-41004530 |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | spec Intratebase 2006: 373 Specfprate2006: 350 |
Declare Max. Power Consumption Of The System | 770 W |
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | SPEC.org |
Server Main Supply | 230V, 10,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 5 years |