Avantor Performance Materials offers a complete line of BeneSphera brand clinical chemistry reagents that utilize the latest formulations and technologies for quantitative determination of substrates, enzymes, and electrolytes in human serum, plasma, or urine. To complement our general chemistry reagents, Avantor offers fully-automated analyzers Urit-PKL PPC 125 has rear Spectrophotometry via filter, high speed fiber transmission system.Auto Dilution for multi-calibration.Collision protection in both vertical and horizontal directions, liquid detection. Auto skip dirty cuvette when testing. Barcode reader optional. Support LIS interface...
Other Specifications Download Specification | |
---|---|
Type Of Portable Mobile Lab | Laboratory in portable case |
Number Of Investigations The Kit Can Perform | 100 |
Whether Kit Performs Liver Function Test:Albumin Test | Yes |
Whether Kit Performs Liver Function Test:Alkaline Phosphatase | Yes |
Whether Kit Performs Liver Function Test:Direct Bilirubin | Yes |
Whether Kit Performs Liver Function Test:Indirect Bilirubin | Yes |
Whether Kit Performs Liver Function Test:Total Bilirubin | Yes |
Whether Kit Performs Liver Function Test:AST(SGOT) | Yes |
Whether Kit Performs Liver Function Test:ALT(SGPT) | Yes |
Whether Kit Performs Liver Function Test:Total Protien | Yes |
Whether Kit Performs Liver Function Test:Globulin | Yes |
Whether Kit Performs Liver Function Test:Albumin/Globulin Ratio | Yes |
Whether Kit Performs Liver Function Test:ALP | Yes |
Whether Kit Performs Kidney Function Tests:Creatinine | Yes |
Whether Kit Performs Kidney Function Tests:Urea | Yes |
Whether Kit Performs Kidney Function Tests:Uric Acid | Yes |
Whether Kit Performs Kidney Function Tests:BUN | Yes |
Whether Kit Performs Kidney Function Tests:EGFR | Yes |
Whether Kit Performs Sugar(Glucose) Test:Fasting | Yes |
Whether Kit Performs Sugar(Glucose) Test:Random | Yes |
Whether Kit Performs Sugar(Glucose) Test:PP | Yes |
Whether Kit Performs Lipid Profile Test:HDL | Yes |
Whether Kit Performs Lipid Profile Test:LDL | Yes |
Whether Kit Performs Lipid Profile Test:VLDL | Yes |
Whether Kit Performs Lipid Profile Test:Triglyceride | Yes |
Whether Kit Performs Lipid Profile Test:HDL/LDL Ratio | Yes |
Whether Kit Performs Lipid Profile Test:Cholesterol HDL Ratio | Yes |
Whether Kit Performs Lipid Profile Test:Cholesterol | Yes |
Whether Kit Performs Lipid Profile Test:CK_MB | Yes |
Whether Kit Performs Electrolytes Test:Sodium | Yes |
Whether Kit Performs Electrolytes Test:Potassium | No |
Whether Kit Performs Electrolytes Test:Chloride | No |
Whether Kit Performs Electrolytes Test:Phosphorus | No |
Whether Kit Performs Electrolytes Test:Calcium | No |
Whether Kit Performs Electrolytes Test:Magnesium | No |
Whether Kit Performs Hematology Test:Haemoglobin | No |
Whether Kit Performs Hematology Test:RBC | No |
Whether Kit Performs Hematology Test:PCV | No |
Whether Kit Performs Hematology Test:MCV | No |
Whether Kit Performs Hematology Test:MCH | No |
Whether Kit Performs Hematology Test:MCHC | No |
Whether Kit Performs Serology Test:Widal | No |
Whether Kit Performs Serology Test:Typhi Dot Igm | No |
Whether Kit Performs Serology Test:Maleria Antigen | No |
Whether Kit Performs Serology Test:Dengue NS1 Antigen | No |
Whether Kit Performs Serology Test:HBSAG | No |
Whether Kit Performs Serology Test:HCV | No |
Whether Kit Performs Serology Test:VDRL | No |
Whether Kit Performs Serology Test:RA Factor | No |
Whether Kit Performs Serology Test:CRP | No |
Whether Kit Performs Serology Test:Pregnancy(UPT) | No |
Whether Kit Performs Serology Test:Semen Analysis | No |
Whether Kit Performs Serology Test:Semen Fructose | No |
Whether Kit Performs Urine Test:Leukocyte | No |
Whether Kit Performs Urine Test:Nitrite | No |
Whether Kit Performs Urine Test:Bilinogen | No |
Whether Kit Performs Urine Test:Protien | No |
Whether Kit Performs Urine Test:PH | No |
Whether Kit Performs Urine Test:Blood | No |
Whether Kit Performs Urine Test:Specific Gravity | No |
Whether Kit Performs Urine Test:Ketone | No |
Whether Kit Performs Urine Test:Bilirubin | No |
Whether Kit Performs Urine Test:Glucose | No |
Whether Kit Performs Urine Test:Appearance | No |
Whether Kit Performs Urine Test:Colour | No |
Whether Kit Performs Urine Test:Reaction | No |
Whether Kit Performs Urine Test:Quantity | No |
Whether Kit Performs Urine Test:Bacteria | No |
Biochemistry Analyzer Provided | No |
Number Of Units Biochemistry Analyzer Provided In The Kit | 1 |
Operating And Reading Method Of Analyzer | True Random acess with Direct reading System |
Technical Specification Of The Biochemistry Analyzer Provided | Spectrophotometry via filter, high speed fiber transmission system |
Sample System,Capacity And Volume Required In The Analyzer | 400 test and 1 to 25 microltr |
Power Supply For Biochemistry Analyzer | 220 vac VDC,Hz VDC,Hz VDC,Hz |
Certifications For Biochemistry Analyzer | ISO,CE |
Type Of Data Logging Option | Quality Control Program with Levy Jennings, Multiple lots, QC charts, etc |
Centrifugation Unit Provided | No |
Number Of Centrifugation Unit Provided In The Kit | 1 |
Technical Specification Of The Centrifugation Unit Provided | NA |
Sample System,Capacity And Volume Required In The Centrifugation Unit | NA |
Power Supply For Centrifugation Unit | NA VAC VAC |
Certifications For Centrifugation Unit | NA |
Type Of Data Logging Option | NA |
Incubation Unit Provided | No |
Number Of Incubation Unit Provided In The Kit | 1 |
Technical Specification Of The Incubation Unit Provided | 400 test and 1 to 25 microltr |
Power Supply For Incubation Unit | 220 vac VDC,Hz VDC,Hz |
Certifications For Incubation Unit | ISO,CE |
Type Of Data Logging Option | Quality Control Program with Levy Jennings, Multiple lots, QC charts, etc |
Data Recorder/Minilaptop Provided | Yes |
Patient Data Management Software Provided | No |
Details Of Patient Data Management Softaware | YES |
Cuvettes Provided | Yes |
Number Of Cuvettes Provided | 60 |
Capacity Of Cuvettes | 1 ml |
Cuvettes Stand Provided | Yes |
Capacity Of Stand And Number Of Stands Provided | 40 |
Material Of The Stand | NA |
Micropipettes Provided | No |
Microtips Provided | No |
Microtip Box Provided | No |
Reagent Containers Provided | No |
Blood Centrifuge Tube Provided | No |
Blood Centrifuge Tube Stand Provided | No |
Capacity Of Stand And Number Of Stands Provided For Blood Centrifuge Tubes | 40 |
Case Or Mobile Carrying Platform Specification | NA |
External Dimension Of The Mobile Lab(the Case): (HeightxWidthxWidth) | 415X565X385 mmxmmxmm |
Power Back Up Facility Provided | Yes |
Type Of Charging Facility | External charging |
Power Back Up Duration | 1 Hrs |
Accessories And Spares Included In Standard Pack | YES |
Additional Safety Features | yes |
Free Service Available | No |
Number Of Free Services, If Provided | NA |
Warranty On Product | 1 |
Supply Of Free Spare Parts Under Warranty | YES |
Annual Maintenance Contract(AMC) Available After Warranty | No |
AMC Contract Period | 1 Year(s) |
Product Code Available On Supplier Website | Yes |
If Yes, Product Code | NA |
Firm Certified To ISO9001:2008 Or Latest | Yes |
Product Is CE Certified | Yes |
If CE Certified, EN/IEC Directives | 98/78 CE |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | Yes |
Test Report No. | 23060CC |
Test Report Date | 24/08/2017 |
Name Of The Lab | Britest Mark Lab |
Address Of The Lab | North Beins Southe Elley Argentina |