Marine Equipment DirectiveMED Approved - Yes Trolley - With Trolley Foam Based Extinguishing Media - NA Halon Based Extinguishing Media as per European Council regulation 2037/2000 concerning use of halons If not applicable write NA - NA.
Other Specifications Download Specification | |
---|---|
Conformity To Standard | EN 3-7 + A1: 2007 & EN 3-82006 with latest amdnt. |
Marine Equipment Directive(MED) Approved | Yes |
Type | Stored Pressure |
Trolley | With Trolley |
Extinguishing Media | Powder Based |
Foam Based Extinguishing Media | NA |
Powder Based Extinguishing Media | BC Powder |
Clean Agents Based Extinguishing Media | NA |
Halon Based Extinguishing Media ( As Per European Council Regulation 2037/2000 Concerning Use Of Halons) ( If Not Applicable Write NA) | NA |
Water Based Extinguishing Media ( If Not Applicable Write NA) | NA |
Wet Chemical Based Extinguishing Media ( If Not Applicable Write NA) | NA |
CO2 Based Extinguishing Media ( If Not Applicable Write NA) | NA |
Expellant Medium | N2 Based |
Class -A Fire Rating For (Powder Based, Water Based, Foam Based,Wet Chemical Based,CO2 Based,Halon Based Fire Extinguisher | 5A |
Class -B Fire Rating For (Powder Based, Foam Based CO2 Based Fire Extinguisher | 34B |
Nominal Permitted Charge For Powder Based Fire Extinguisher | 6 kg |
Nominal Permitted Charge For Water Based, Foam Based, Wet Chemical Fire Extinguisher | NA Ltrs |
Nominal Permitted Charge For C02 Based Fire Extinguisher | NA kg |
Nominal Permitted Charge For Halon Based Fire Extinguisher | NA kg |
Nominal Permitted Charge For Clean Agents Based Fire Extinguisher | 1 kg |
Discharge Time | 6 second |
Discharge Range Of Fire Extinguisher | 2 meters |
Weight Of Filled Portable Fire Extinghuisher | 20 kg |
Operating Temperature, Max | 60 ° C |
Test Pressure(cylinder) | 60 Bar |
Height Of Cylinder | 175 mm |
Diameter Of Cylinder | 75 mm |
Rechargable | Yes |
Color Coding | Signal Red |
Fire Extinguisher Suitable For Class -C Fire | Yes |
Fire Extinguisher Suitable For Class -D Fire | No |
Fire Extinguisher Suitable For Class -K Fire | No |
Fire Extinguisher Suitable For Class -F Fire | No |
Availability Of Test Report From Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification | Yes |
Test Report No. | IS/2017-18 |
Test Report Date | 01/03/2018 |
Name Of The Lab | FTRL |
Address Of The Lab | DELHI |
Service Pressure | 60 Bar @ ° C |
Guarantee Against Corrosion | 1 Years |
Welding On The Extinguisher Body | Yes |
Cylinder/Bottle Material | MS |