LUIT Minerals is the first water treatment machineries manufacturing company in Northeast, under Department of Industries Commerce, Government of Assam that designs and manufactures water filters for iron, manganese and arsenic removal. Our superior products come with ISO 90012015, 140012004 Certification .Supplying ready made portable iron water filters and customized large iron removing plants is our expertise. We provide iron removing filters up to 80000 Litre with manual and automatic backwash system. The tanks vessels are made of Fibre-reinforced plastic, while for special applications we also provide stainless steel tanks on request..
Other Specifications Download Specification | |
---|---|
Iron Removal Unit | With |
Prefilter Provided With Flushing Valve In The Iron Removal Unit | YES |
Iron Removal Unit Suitable For Water Supply Equipment | Hand Pump |
Discharge Capacity Of The Iron Removal Equipment | 4000 Litre LPH |
Material Of Body Of Iron Removal Equipment | FRP |
Diameter Of Vessel Of Iron Removal Equipment | 1865 mm mm |
Height Of Vessel Of Iron Removal Equipment | 60 mm mm |
Number Of Iron Removal Vessel | 1 nos Nos |
Minimum Thickness Of Vessel Of Iron Removal Equipment | 3 mm mm |
Material Of Strainer Plate Of Iron Removal Equipment | PVC |
Diameter Of Strainer Plate Of Iron Removal Equipment | 30 NB mm mm |
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment | 5 mm mm |
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment | 2 Nos Nos |
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment | 1 Nos Nos |
Material Of Strainer In Strainer Plate Of Iron Removal Equipment | PVC |
Quantity Of Iron Removal Media In Iron Removal Vessel | Eco Friendly Kg Kg |
Quantity Of Filter Media In Iron Removal Media | 30 kg Kg |
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel | 40 |
Back Wash Valve In Iron Removal Vessel | Inbuilt auto back wash system by manually operated valve ( pumping is not required for back wash) |
The Accumulated Ferric Is Removed From The Media While Back Washing | YES |
Maximum Iron Content Of Inlet Water | 20 ppm ppm |
Maximum Iron Content Of Outlet Water | 0.3 ppm |
Process By Which Iron Is Removed From Water By Iron Removal Media | . Iron removal media works through oxidation process. 2. Ferrous is oxidized to ferric state and gets filtered in the media which acts as a filter bed also. |
Life Of Iron Removal Media | 2 years Years |
Cost Of Refilling Of Iron Removal Media | 26500 Rupees |
Life Of Iron Removal Unit | 10 years Years |
Protective Coating Of Iron Removal Vessel | coat forming |
Inlet Pipe Size Of Iron Removal Unit | 2.5 mm mm |
Space Required For Installation Of Iron Removal Unit | 5 to 7 square metres Square Metres |
Number Of Valves In Iron Removal Unit | 2 nos Nos |
Materal Of Valve Of Iron Removal Unit | UPVC |
Diameter Of The Valve In Iron Removal Unit | 10 mm mm |
Pressure Gauge In Iron Removal Unit | YES |
Pressure Release Valve In Iron Removal Unit | YES |
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit | 55 kg/square cm Kg/square cm |
Weight Of Iron Removal Unit | 45 Kg |
Warranty Period Of Iron Removal Unit | 2 years Years |
Arsenic Removal Unit | Without |
Discharge Capacity Of The Arsenic Removal Unit | 0 LPH |
Arsenic Removal Unit Suitable For Water Supply Equipment | Hand Pump |
Material Of Arsenic Removal Vessel | 0 |
Diameter Of Arsenic Removal Vessel | 0 mm |
Height Of Arsenic Removal Vessel | 0 mm |
Minimum Thickness Of Arsenic Removal Vessel | 0 mm |
Number Of Arsenic Removal Vessel | 0 Nos |
Material Of Strainer Plate Of Arsenic Removal Vessel | 0 |
Diameter Of Strainer Plate Of Arsenic Removal Vessel | 0 mm |
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel | 0 mm |
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate | 0 Nos |
Material Of Strainer In Arsenic Removal Strainer Plate | 0 |
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel | 0 Kg |
Media Used For Removal Of Arsenic From Water | 0 |
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel | 0 |
Maximum Arsenic Content Of Inlet Water | 0 ppm |
Maximum Arsenic Content Of Outlet Water | 0.01 ppm |
Life Of Arsenic Removal Media | 0 Years |
Cost Of Refilling Of Arsenic Removal Media | 0 Rupees |
Life Of Arsenic Removal Unit | 0 Years |
Protective Coating Of Arsenic Removal Vessel | 0 |
Inlet Pipe Size Of Arsenic Removal Unit | 0 mm |
Space Required For Installation Of Arsenic Removal Unit | 0 Square Metres |
Number Of Valves In Arsenic Removal Unit | 0 Nos |
Materal Of Valve In Arsenic Removal Unit | 0 |
Diameter Of The Valve Of Arsenic Removal Unit | 0 mm |
Pressure Gauge In Arsenic Removal Unit | YES |
Pressure Release Valve In Arsenic Removal Unit | YES |
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit | 0 Kg/square cm |
Weight Of Arsenic Removal Unit | 0 Kg |
Warranty Period Of Arsenic Removal Unit | 0 Years |
Iron Removal Media Conform To International Standard | National Science Foundation, USA |
Arsenic Removal Media Conform To International Standard | National Science Foundation, USA |
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate | YES |
Field Testing Kit For Testing Iron & Arsenic Is Provided | YES |