MICROTEK 10KVA, 360V 9360VAH ONLINE UPS, WITH 30 BATTERIES OF Exide 26AH EP26-12. Microtek UPS 10 KVA is designed to take Higher Loads. It runs Load up to 8 Kilowatts It is the best suited UPS for High Capacity Sophisticated.True Online Double Conversion Technology High End IGBT based High End Micro Controller. Automatic Battery Charging in UPS Off Mode Wide Input Voltage Range Advanced Battery Management Short Circuit and Overload Protection Hot Standby Optional Galvanic Isolation Available at 3 Phase In 1 Phase out. Specially Designed to Suit Indian Power and Environment Conditions Generator Compatible Over Temperature Protection..
Other Specifications Download Specification | |
---|---|
Rating In KVA | 10 KVA |
Technology | IGBT-PWM with inbuilt isolation transformer |
Input Power | Three phase 300 V - 450V sinewave,50Hz |
Output Power | single phase 230V 1 sinewave,50Hz |
Backup Time | 60 Minutes |
Minimum VAH | 9360 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 3 % |
Overall Efficiency | 95 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | Without trolley but with Rack |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | 4465 |
Type Test Certificate Date | 27-02-2017 |
Name Of Lab | MICROTEK |
Address Of Lab | ROHTAK ROAD NEW DELHI |
Supply & Commissioning | YES. BUT SITE SHOULD BE READY |
Warranty | 1 Years |