Microprocessor based control system for separation of blood components liked packed cells, platelets rich plasma, platelet consecrate plasma etc. Totally CFC refrigerated fluid and insulation, with programmable memory, swing bucket blood bank rotor, Centrifuge force, and speed variations, Temperature range, programmable time, control display, motor imbalance detection, stainless steel chamber, security, power requirements, atmosphere ambience, protection , product is certified by USFDA, quality ISO certified with IEC class I electrical safety.
Other Specifications Download Specification | |
---|---|
Centrifuge Design | Floor Standing |
Centrifuge Type | Ultra centrifuge |
Speed Mode | Variable Speed |
Rotor Configuration | Swinging Bucket |
Interchangeable Rotors | YES |
Material Of Rotor | Steel |
Finish Of Rotor | Powder coated |
Autoclavable Rotor At 121 Degree Celsius | YES |
Type Of Drive Motor | Brushless DC Motor |
Controler Type | Microprocessor Controlled |
Body Material | Metal Alloy |
Finish Of Body | Powder coated |
Base Material | Steel |
Lid Type | Opaque |
Lid Material | Steel |
Lid Lock Detector | YES |
Emergency Lid Lock Release | YES |
Automatic Braking | YES |
Number Of Sample Tubes Testable Simultaneously | 12 |
Volume Of The Tube Testable | 100 ml |
Maximum Speed | 4500 RPM |
Minimum Speed | 100 RPM |
Speed Increment Step, If Variable Speed | 5 RPM |
Speed Control Accuracy Of Set Speed (+/-) | 1 RPM |
Maximum Relative Centrifugal Force(RCF) | 5370 x g |
Calibration | Automatic Calibration |
Temperature Control Method | Refrigerated |
If Refrigerated, Refrigeration System Free From CFC/HCFC | YES |
Temperature Setting Range(increment Step) | -20 TO +40 Degree Celcius |
Temperature Control Accuracy Of Set Temperature(+/-) | 35 Degree Celcius |
Acceleration Time (full Speed) | 5 sec |
Deceleration Time( Full Stop) | 9 sec |
Number Of Acceleration/deceleration Profiles In-built | 9 |
Timer Provided | YES |
Timer Setting (Increment Step) | 59 SEC TO 99 MIN min min |
Input Method/Interface | Digital Front Panel Without Glove mode |
Display Option/Output Read Out Option | Digital |
Type Of Data Logging Option | RS232 |
Rotor Imbalance Detection | YES |
Auto Cutoff | YES |
Pulse Mode | YES |
Programmable | YES |
Number Of Storable Programmes,If Programmable | 21 |
Input Voltage With Phase | 220 V |
Power Consumption | 4500 W |
Input Current | 15 A |
Noise Level (maximum) | 55 db |
Ambient Operating Temperature | 35 Degree Celcius |
IP Rating Or Ingress Protection Rating | 21 |
External Dimension: Height | 1050 mm |
External Dimension: Width | 800 mm |
External Dimension: Depth | 850 mm |
Weight Including Default Rotor | 350 kg |
Accessories And Spares Included In Standard Pack | SWING OUT ROTOR, BUCKETS WITH 2 COMPARTMENT, SINGLE BUCKET AND BAG HOLDER |
Additional Safety Features | Auto cutoff for Over speed/imbalance/lid lock/temperature limit |
Free Service Available | YES |
Warranty On Rotor And Machine | 2 Years |
Supply Of Free Spare Parts Under Warranty | YES |
Annual Maintenance Contract(AMC) Available After Warranty | YES |
AMC Contract Period | 1 Years |
Product Code Available On Supplier Website | YES |
If Yes, Product Code | 84211999 |
Firm Certified To ISO9001:2008 Or Latest | YES |
Product Is CE Certified | YES |
If CE Certified, EN/IEC Directives | ISO CE |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | ON DEMAND |
Test Report No. | ON DEMAND |
Test Report Date | ON DEMAND |
Name Of The Lab | ON DEMAND |
Address Of The Lab | ON DEMAND |
Number Of Free Services, If Provided | 2 |