PETROL START PETROL RUN PORTABLE GENERATOR, RATED OUT PUT 5000 VA, 220 VOLT plus minus 6 percent , 50 Hz. SINGLE PHASE, UNITY POWER FACTOR, RECOIL START and Key Start / SELF START, with Certification GSR 535 E 7.8.2013 S.No. 88, SI As per IS 12824 and IS 4722 / 2001, 20 Ltr Fuel tank and with battery and charger, Voltage regulation form no load to full load with in 15 percent, Generator compliance as per latest CPCB Norms..
Other Specifications Download Specification | |
---|---|
Portable AC Generating Set Comprising Of Air Cooled 4 Stroke Single Cylinder Engine And Alternator. | yes |
Starting And Running | Petrol start, Petrol run |
Rated Output At Unity Power Factor At STP | 5000 VA |
Starting Type | Electric Self start |
Power Output | 220 V AC |
Make And Model Of Portable Generator Sets | HIMALAYAN POWER, GE 5000 RS |
Make And Model Of Engine | HIMALAYAN POWER, HM 192 PY |
Make And Model Of Alternator | HPM GE 5000 RS |
Efficiency Of The Alternator | 74 % |
Noise Level Of Portable Generator | 72 db |
Dry Weight | 132 Kg |
Provision Of Voltmeter And Ammeter In The Output Circuits | yes |
Generator To Comply Temp. Rise Limits Given In IS:4722/92 | yes |
Limits Of Vibration | LESS THAN 3 MM PER SEC mm per sec |
Period For Which The Generator Is Capable Of Delivering Declared Output | 6 hours |
Type Approval For Emission Level And Noise Level | yes |
TTC Number & Date | L-0594, 29/09/2016, L-0974, 28/07/2016 |
Dimension Of Genset In Mm LxWxH | 990 X 530 X 710 |
Electric Start Gen Sets Shall Have Maintenance Free Battery And BatteryCharger With Suitable Starter In Case Of Electric Start. | yes |
Compatibility Of Battery Ratings And Motor Starters With The Respective Engines In Case Of Electric Start. | yes |
The Generating Set Shall Be Fitted With Fuel Tank Of A Capacity To Give Continuous Operation For Minimum 5 Hours At Rated Full Load And Fuel Should Not Spill Out Of The Lid Of The Tank Due To The Vibration. | yes |
Fuel Tank Capacity Of Generator | 20 Ltr |
Generating Set Should Have Low Lubricating Oil Alert System | yes |
Availability Of Type Test Report From Central Government/NABL/ILAC Accridiated Laoratory To Prove Conformity To The Specification For Each Rating For Portable Generator Set . | yes |
Test Report Number | ERTL(N)/90(4)-(2016-2017)/C0568 |
Date Of Issue Of Test Report By Laboratory | 29/03/2017 |
Name And Address Of Laboratory | ERTL NORTH, OKHLA NEW DELHI 110020 |
COP And TAC Declaring Make And Model Of Engine/Portable Generator Sets , Shall Also Be Provided To The User On Demand. | yes |
Portable Generator Sets , Shall Also Be Provided To The User On Demand. Shall Meet The Requirements Of EnvironmentalProtection Rules 1986 As Laid Down By Min. Of Environment & Forests Read With GSR 371 E Dated 17.5.2002,GSR And Latest Guide Lines520Edated 1.7.2003 , No.448 E Dated 12.07.2004 , GSR 771E Dated 11.12.2013 GSR 232E Dated 31.03.2014,Gazette Notification No.167 Dated. 31.03.2014 And Gazette Notification No. 578 Dated. 11.11.2014.in Respect Of Noise And Emission Norms. The Latest Amendments To Above GSRs Shall Be Applicable As And When Amended By Ministry Of Environment And Forest. | yes |
Warranty | 2 year |
Battery Ah Capacity In Case Of Electric Start Generator. | 25 Ah |