× All the transactions performed on 2.0 is available here. To access Market click "Home".

emerson 1 kva online with 30 mins back up 960 vAH (emerson vertiv)(gxtmt +cx lb)

` 29,700.00

  • MRP: `33019.00

IGBT Based RectifierTrue Online Double Conversion with DSP Control Technology for High Performance and Reliability.New Graphical LCD Display Provides UPS Data, Alarms and Helps in faults diagnostics and trouble shooting.Double Conversion Efficiency upto 90.Active Input Power Factor Correction 0.99.0.8 Output Power Factor.Wide Input Voltage window 110 - 280 Vac for Indian Environmental Condition and for Optimized Battery Performance.Configurable Output Voltage 200/208/220/230/240 Vac.Generator Compatible with Wide Input Frequency Range 40 Hz-70 Hz.4 Stage Extendable Charging Design for optimized Battery Performance.Adjustable Battery Charging Current 1/2/4/6 Amps according to Battery Capacity and Rating.50/60 Hz Automatic Frequency Converter Mode.Intelligent Monitoring with Standard RS232/USB Port Plus Slot Available for RS485/Dry Contact/SNMP Card.Inbuilt OVCD..

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 936 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1 KVA
Technology IGBT-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 936 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 5 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. ETDC mH/T&M/173
Type Test Certificate Date 19-3-15
Name Of Lab etdc
Address Of Lab MAHARASHTRA
Supply & Commissioning yes with installation
Warranty 2 Years

Price Dekho Price Dekho Price List in india