Oxygen Concentrators Model Mark 5 Nuvo Lite FDA ApprovedSpecification-Oxygen flow rate 0-5 LPM-Output oxygen pressure 7 Psi Oxygen purity 90 to 95 at 0-5 LPM Weight 13.60 kg Sound level 40 dBA Power consumption 290 W Dimensions H x W x D 360 x 220 x 580 mm Optional specification Oxygen Monitoring System, Note Please Ignore Below Specification.
Other Specifications Download Specification | |
---|---|
Conformity To ISO 80601-2-69:2014 Of The Medical Electrical Equipment – Part 2-69: Particular Requirements For Basic Safety And Essential Performance Of Oxygen Concentrator Equipment | Yes |
Flow Rate (Minimum) At 93% + - 3% Oxygen Purity | 5 Litres per minute |
Type | Portable |
Battery Duration (If Battery Operated Or Electrical Cum Battery Operated) | 0 Hrs |
Battery Charging (If Battery Operated Or Electrical Cum Battery Operated) | 0 Hrs |
Oxygen Outlet(s) | Single or Dual |
Outlet Pressure | 7 KPa |
Power Consumption | 290 Watt |
Operating Temperature Range | 40 degree C |
Operating Humidity Range | 30 % |
Operating Altitude Range | 2287-4000 Meters |
Type Of Operation | Continuous Flow Type |
Adjustable Air Delivery Mechanism | Yes |
Oxygen Concentration Monitor | Yes |
Oxygen Tank Capacity | 5 Ltrs |
Noise Level | 40 dB |
Continuous Flow | 5 LPM |
Digital Display | LCD |
Audio Alarm | YES |
Visual Alarm | YES |
Alert Of Technical Fault | YES |
Alert Of Wrong Battery | YES |
Alert Of Depleted Battery | YES |
Alert Of High Breath Rate | YES |
Alert Of Low Oxygen Purity | YES |
Alert Of No Breath | YES |
Alert For No Flow | YES |
Alert For Low Flow | YES |
Alert For High Flow | YES |
Alert Of Low Pressure | YES |
Alert Of High Pressure | YES |
Alert Of High Temperature | YES |
Alert For Power Failure | YES |
Alert For Service Requirement | YES |
Weight | 13.6 Kg |
Dimensions (Length) | 36 mm |
Dimensions (Width) | 22 mm |
Dimension (height) | 58 mm |
Flame Retardant | YES |
Manufacturer Warranty Period | 3 Years |
Spare Part Availability | YES |
Comply With International Standards | YES |
Name Of International Standards | ce |
FDA Approved | YES |
Availability Of Test Report CE Or EC Certification In Accordance With Appendix II(excluding Section 4) Of Medical Device Directive 93/42/EC & Its Amendment Or Equivalent | ce |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | fda |
Test Report No. | yes |
Test Report Date | yes |
Name Of The Lab | yes |
Address Of The Lab | yes |
Power Source | Electrical Operated |
Power Efficiency | 5 W/LPM |