Fluke 115 Field Service Technicians Multimeter.1-Compact true-rms meter.2-All you need for general electrical and electronic testing.3-Engineered by Fluke, with a three-year warranty.4-Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.Also check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electricians Multimeter with Non-contact voltage.Large white LED backlight to work in poorly lit areas.Resistance and continuity. Min/Max/Average to record signal fluctuations.CAT III 600 V safety rated. All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TV listed and VDE. AC Voltage Measurement Accuracy percent is 1.0 percent plus minus 3 digit..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.5 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 1 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | NA % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | -10 °C to 50 °C |
Operating Humidity (RH) | 90% |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 9V Alkaline |
Total Voltage Of Battery | 9V |
Standard Accessories Supplied With The Equipment | Model includes the following: Holster Installed 9 V battery Test leads User manual |
Dimensions (H X W X L) | 167.1 mm X 85.1 mm X 46.0 mm mm x mm x |
Weight | 550gms gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | Statement of calibartion practises and CSA test certificates are provided |
Test Report Date | Statement of calibartion practises and CSA test certificates are provided |
Name Of The Lab | Statement of calibartion practises and CSA test certificates are provided |
Warranty | 3 Year |