× All the transactions performed on 2.0 is available here. To access Market click "Home".

b p machine handheld type (b p apparatus)(handheld)

` 800.00

  • MRP: `1100.00

B P apparatus handheld portable good quality with both adult and pediatric cuff.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Conformity to Indian Standrad for SPHYGMOMANOMETERS - IS 7652 latest for Aneroid
  • ISI MARKED - NA for digital
  • CM/L No and validity date - 00
  • Type - Portable
  • Range: Pressure measurement - 0 to 300 mmHg
Other Specifications Download Specification
Type Of SPHYGMOMANOMETERS(B.P.Apparatus) Aneroid
Conformity To Indian Standrad For SPHYGMOMANOMETERS IS 7652 latest for Aneroid
ISI MARKED NA for digital
CM/L No And Validity Date 00
Measuring Device Mechnical
Type Portable
Measurement Method others
Display For Digital BP Instrument: NA for others
Range: Pressure Measurement 0 to 300 mmHg
Range:Pulse Measurement For Digital With Accuracy ± 5%. 40 to 200 per minute
Accuracy:Pressure Measurement ± 3 mmHg
Pressure Detection Capacitive Pressure sensor
Inflation Automatic Pressure Application by pump
Deflation And Rapid Air Release Automatic Pressure Release Valve
Cuff Range Small (18-22)cm
Dimensions Of The Equipment 00 mmXmm
Dimensions Of The Display Screen 00 mmXmm
Operating Temperature 0 to 55 °c
Stroage Temperature (-10) to 55 °c
Power Source:Chargeable 4 Nos AA Size Batteries.Operated With Battery Charger(for DIGITAL). Yes
Type Of Battery(4 Nos AA Size) Alkaline
Automatic Power Off If System Is Idle For 3 Minutes. Yes
Weight 00 Kgs
CE Marking Certificate For B.P. Apparatus Model. Yes
For Digital Sphygmomanometer ,Availability Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A). Dry Heat Test (For 16 Hrs At A Temp. Of 55degree C In Accordance With IS: 9000/part-3/section-3/1977)latest. Yes
B). Cold Test(For 4 Hrs At A Temp. Of (-10) Degree C In Accordance With IS: 9000/part-2/section-3/1977latest. Yes
C).Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 55 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981)latest. Note:- The B.P.Instrument Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, B.P.Instrument Shall Be Functional. " Yes
Availability Of Type Test Report Covering Complete Test Parameters As Per IS3390 Latest For Mercurial And IS7652 Latest For Aneriod Type, From Any ILAC/NABL Accredited/Central Gov. LAB.For Digital Type Including Environmental Test From Any ILAC/NABL Accredited/Central Gov. LAB Yes
Test Cetificate No. 00
Test Report Date 00
Name And Address Of The Lab Where Test Conducted. 00
Others Certificate Ie ROHS,WHO,GMP Etc. 00
Conformity To OILM-R-16-1 And OILM-R-16-2 For Both Non-invasive Mechanical Sphygmomanometers And Non-invasive Automated Sphygmomanometers Are For Guidance And All The Gazette Of India Related To Legal Metrology Issued Time To Time, Are Applicable To The Specification As Well As To The Product. Yes
Warranty Time 1 Year

Price Dekho Price Dekho Price List in india