1Film Format- Sheet films 2Film Size Minimum I00X I00mm4 X 4,Maximum358x43214 x 173FilmTransportation Continuous Roller Transport, Auto Start/Stop4Processing Time90-200sMulti speed5Processing Capacity@9G slime 241x305mm 47films /h, 432 x 358mm 82 films/h 6 Developer Temperature28-3 7C82-99F adjustable7 Fixer Temperature2B-37C82-99F adjustable8 Drier Temperature Max 70e adjustable9 Bath Opacities D/F/W 5S/5Lwith overflow drain10 Replenishment Tanks 25Leach for developer and fixer11 Chemical replenishment 450-750 ml_/m adjustable automatic12 Chemical Circulation 10.5 l/mincontinuous13 Water Replenishment1.9 l/minProcessing auto On I Off0.0l/min in stand by 14 Power Consumed1.4 kWhprocessing 0.1 kj/s stand by Dimensions78cmI. 59 cmw. 42cmh Footprint046m2 Weight35kg empt 50 kg filled.
Other Specifications Download Specification | |
---|---|
Table Top Automatic Medical X Ray Film Processor Machine | Yes |
The Assembly Made Up Of Material Non Corrosive | Yes |
Length Of Machine | 78cm |
Width Of Machine | 59cm |
Height Of Machine | 42cm |
Weight (Empty) | 35kg |
Auto Developer , | Yes |
Auto Fixer | Yes |
Auto Washer | Yes |
Auto Dryer | Yes |
Material Of Cabinet | ABS Plastic |
Rollers Mechanism | Motrised |
Rollers Material | PVC with inner pipes of SS-304 Grade |
Minimum Film Size Length X Width | 100 x 100 |
Maximum Film Size Length X Width | 356 x 432 |
Continious Film Roller Transport And Auto Start And Stop Facility | Rigid PVC |
Processing Time: 90 Sec To 200 Sec In Steps Of Six Second With LED Display | Yes |
Processing Capacity Of Size 356mm X 432 Mm In 90 Second Mode | Yes |
Minimum Capacity Of Fixer,Washer And Developer Tank | 5 |
Mimimum Capacity Of Replenishment Developer And Fixer Tank With Overflow Drain Facility | 25 |
Automatic Replenishment | Yes |
Developer And Fixer Temprature Adjustable Throught Automatic Temprature Controller | Yes |
Operating Temp Range | (28-37 )degree degree |
Dryer Temprature(maximum) | 70 degree |
Power Supply | 230 volt A.C |
Maximum Power Consumption | 1.4 kwh |
Water Filter Compatible With Equipment Supplied With Equipment | Yes |
Manual ,auto Stop With Power Saver/standby Mode Facility | Yes |
High Voltage Test 1.5 KV For I Minute | Yes |
Minimum Insulation At 500 V DC | yes |
Instruction Manual Supplied With Equipment | yes |
Chemicals/Materail For Running Equipment For Minimum One Month | yes |
Radiology Certificate For Processed Film | yes |
Availibility Of Type Test Report For Performance Test | as per demand |
Test Report To Shown To Buyer As And When Required | Yes |
Test Report Number & Date | as per demand |
Name & Address Of Laboratory | as per demand |
Certifiacation | iso9001,iso13485,ce |