203 Single Dell Power Edge M630 Blade Server. Per Blade Server Config 2X Intel Xeon E5-2690 v4 2.6GHz,35M Cache,9.60GT/s QPI,Turbo,HT,14C/28T 135W Max Mem 2400MHz, 4X 32GB RDIMM, 2400MT/s, Dual Rank, x4 Data Width, 2X 600GB 10K RPM SAS 12Gbps 2.5in Hot-plug Hard Drive..
Other Specifications Download Specification | |
---|---|
Form Factor | Rack |
Processor Make | Intel |
No. Of Slots In Chassis | 16 |
Blade Server | With Chassis |
No. Of Blade Server In Chassis | 16 |
Max. Number Of Sockets Available On Blade Server | 2 |
Max. Number Of Sockets Populated With Processor | 2 |
Number Of Core Per Processor | 14 |
Processor Configuration | E5-2690 v4, 14 core, 2.6 GHz with 35 MB smart cache memory, 135 watt |
Chipset Compatible With CPU | Intel C610 |
Motherboard (OEMcompatible With CPU) | Yes |
Number Of PCI Slots (Express Gen 3.0 Min.) | 2 |
Max Nos Of PCI Lanes | 40 |
Memory ( DDR4 RAM Min.) | 128 GB |
DDR4 RAM Upgradable Upto (Minimum) | 1500 GB |
DIMM Slots (Minumum) | 24 |
Hard Disk Drive Capacity | 2*600 GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 10000 RPM |
RAID Controller Caches | Nil MB MB |
RAID Controller | H330SAS |
RAID Controller Ports | 8 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
USB Ports | 3 |
Multifunctional Ports (min.) | Nil |
Fiber Channel Ports (min.) | 2 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Available |
FC HBA Dual Port Card Speed | 16 |
Chassis Shall Be; 1. Suitable To Accommodate The Blade Servers. 2. Supplied With Interconnect Modules, Power Supplies, Fans & Management Modules. 3. Include All Accessories So That It Can Be Mounted On An Industry Standard 42U Rack. 4. Fully Populated With Power Supplies Redundancy. 5. Supplied With The PDUs To Connect Power Cables To The Chassis Power Input Terminals. 6. Fully Populated With Fans For Cooling With Adequate Redundancy Built In For The Entire Enclosure & Its Components Along With DVD ROM. 7. Complete With Required Number Of Redundant Managed Ethernet Switches To Provide At Least Two Nos. Of Ports Of 10 Gb/s Connectivity. Redundant Fibre Channel Switch To Provide At Least 2 Nos. Of 16 Gb/s Fibre Channel Connectivity To The External SAN Storage. 8. Management Module Which Provides A Single Point Of Control For Intelligent Management Of The Entire Console. It Should Provide Setup & Control Of Enclosure, Should Report Asset And Inventory Information For All The Devices In The Enclosure. It Should Report Thermal & Power Information On Per Server & Per Enclosure Basis And It Should Provide KVM Functionalities & Access For All The Server Blades From The Management Module. | NA |
Avaialbility Of List Of Installations During Last 1 Year Along With Peformance Report From The Users Department. | Yes |
Avaialbility Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | NA |
Name Of Lab | NA |
Address Of Lab | NA |
BIS Registration Number, Under Compulsory Registration Scheme (CRS) Of Deity | NA |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | 1310 and 873 |
Declare Max. Power Consumption Of The System | Through Chasis |
Availability Of Documentary Evidence In Support Of Model Quoted In Commercial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | NA |
Server Main Supply | 230V, ±10%,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 3 |