Fluke Power Quality Analsyer Fluke 434-II along with standard Accessories.
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Three phase |
Display Type | LCD Backlit |
Display Mode | 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD |
Number Of Current Channels | 4 Nos. |
Number Of Voltage Channels | 5 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 1 V to 1000 V Volts |
Measurable Voltage Accuracy | ± 0.5 % |
Measurable Voltage Resolution | 0.1 Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 0.5 A to 6000 A Ampere |
Measurable Current Accuracy | ± 0.5 % ± 5 counts |
Measurable Current Resolution | 0.5 A to 600 A -- 0.1 A & 5A to 6000A --- 1A Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 6000 MW KW |
Power Accuracy | ± 1 % ± 10 counts |
Power Resolution | 0.1 W to 1MW Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 42.50 Hz to 69.00 Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | ± 2.5 % |
Resolution In Measurement Of Total Harmonics Distortion | 0.10% |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 1 to 50 |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | ± 0.1 % |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | NA |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | ± 0.1 % |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1.0 > 2.8 |
Measurable Crest Factor Accuracy | ± 5 % |
Measurable Crest Factor Resolution | 0.01 |
Screen Memory | Available |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 8GB SD Card memory MB |
Type Of Battery Used | Lithium-Ion |
Battery Backup | Up to 8 hours Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 2kg Grams |
Dimensions(LXWXH) | 265 x 190 x 70 mm cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery degree celsius |
Operating Humidity | " +10 °C ~ +30 °C: 95 % RH non-condensing +30 °C ~ +40 °C: 75 % RH non-condensing +40 °C ~ +50 °C: 45 % RH non-condensing" % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Provided |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | CAT III 1000Volts and CAT IV 600V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 3948372 |
TTC Report Date | 15th July 2017 |
Name Of Lab | Fluke Corporation |
Address Of Lab | USA |
Interface | USB |