v-guard solar etc water heater v-hot series 300 lpd (v-guard)(v-hot 300 lpd)

` 51,200.00

  • MRP: `61000.00

V-Guard Solar Water Heater of 300LPD ETC Non Pressurized System including 2 KWBack up Heater, roof top.Generates hot water without electricity or any other fuelHuge saving on electricityStorage tank is made of food Grade SS304L with Aluminium Stucco cladding. High quality PUF insulation minimizes the heat loss of water inside the tankEfficient performance in winter and partially cloudy daysHigh quality vacuum tubesHuge saving on electricity and fuel chargesType of Thermal Insulation - Polyurethane Foam PUFAbsorber coating - AlN-SS-Cu coatingInner tank Material- Stainless steel 304-LBackup Heater Connector - 1ompact size, low height lightweightFitted with Sacrificial AnodeGreater absorption area, auto sun tracking due to circular shape of vacuum tubesISI Electric backup heater optional to the customerAdvanced technology at competitive rateOperating Pressure - Max .4 kg/cm2Evacuated Glass Tube with absorber coating.Outer shell Material- Aluminium Stucco SheetInput / output..

  • Availability: 98 In Stock
  • Min. Qty. Per Consignee: 1
  • BIS Approved - Yes
  • If Yes , Mention CM/L No. otherwise put NA - NA
  • Model Number of Solar Water Heater System - V-Hot 300 LPD
  • Region - Type 2 Warm (Areas where ambient tenmp is moderate and do not go normally below 5 degree C)
  • Electrical Heater ( Back up ) Capacity - 2 kw
Other Specifications Download Specification
Confirmity To Standards For Solar Water Heating System -Code For Acceptance IS : 12976:1990 with latest amndmt.
BIS Approved Yes
If Yes , Mention CM/L No. Otherwise Put NA NA
Model Number Of Solar Water Heater System V-Hot 300 LPD
Solar Water Heating System Compaitabilty With Heat Exchange Solar Water Heating System without Heat Exchanger
Region Type 2 Warm (Areas where ambient tenmp is moderate and do not go normally below 5 degree C)
Rated Capacity In Litres Per Day 300 LPD
Aperture Area Of Collector , Sq. Meteres 1.8 Sq Meter
Electrical Heater ( Back Up ) Capacity 2 kw
Capacity Of Make Up Tank( SWHS With Heat Exchanger Only ) NA Ltrs
Solar Flat Plate Shall Be BIS Marked And As Per IS :12933/2003 With Amndmt 1 To 3 Yes
Type Of Cover Plate Conforming To IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum
Solar Transmittance For Cover Plate At Normal Incidence 82 %
Material For Collector Box Aluminium
Numbers Of Collectors 29
Minimum Channel Section Thickness For Sides ( For Al Based) MUST BE >=1.4 Mm Otherwise Put 0 For CRCA Material NA mm
Minimum Thickness Of Sheet For Bottom ( For Al Based), MUST BE >=0.45 Mm Otherwise Put 0 For CRCA Material NA mm
Minimum Thickness Of Sheet Used As Support For Glass Retaining ( For Al Based), MUST BE >=1.2 Mm Otherwise Put 0 For CRCA Material NA mm
Thickness Of Sheet For Entire Body ( For Al Based), MUST BE >=1.0 Mm Otherwise Put 0 For CRCA Material NA mm
CRCA Material Thickness, Minimum MUST BE >=0.91 Mm Otherwise Put 0 For Al Material NA mm
Riser And Header Assembly Desigmed For Working Pressure 24.5 K Pa Shall Be Tested For Leakage At A Minimum Hydraulic Pressure Of 490 K Pa Yes
Number Of Absorber Sheets Per Collector 29
Numbers Of Header Tubes 29
Numbers Of Riser Tubes 29
Diameter Of Header Tube 24.5 mm
Diameter Of Riser Tube 11.5 mm
Thickness Of Header Tube 0.71 mm
Thickness Of Riser Tube 0.56 mm
Material Of Riser /Header For Absorber Copper Only
Distanace Between Risers From Center To Center 120 mm
Material Of Sheet For Absorber Aluminium
Collector Box Insulation Back and sides
Thermal Resistance Of Insulation In Square Degree For Back Face(must Be Greater Than >=0.96) NA W/K m
Thermal Resistance Of Insulation In Square Degree For Side Face(must Be Greater Than >=0.47) NA W/K m
Gasket And Grommets Shall Confirm To IS 12933/2003 With Latest Amndmt. Yes
Material For Hot Water Storage Tank SS304
Name The Material If Choose Others Stainless Steel
Non Pressure Type Hot Water Storage Tank Yes
Position Of Hot Water Tank Horizontal
Thickness Of Sheet Of Hot Water Tank NA mm
Hot Water Tank Insulation Density ( High Density PUF Insulation For 32 Kg/ Meter Cube Or Higher Density 40 mm
Hot Water Welding TIG
Coating Material For Hot Water Tank Polyster Epoxy Plus Balck Epoxy based Paint
Thickness Of Coating 55 micron
Tank Stand Material Mild Steel
Size Of Tank Stand (L X W X H ) Must Be Greater Than 38 X38 X 4 XX XX XX mm3
Type Of Heat Exchanger cage Type
Material For Heat Exchanger Copper
Thickness Of Tube Of Heat Exchanger , Minimum 22 SWG 22
Heat Transfer Rate For Heat Exchanger , Must Be Greater Than 0.24 Sq Meter Per 100 LPD Capacity 0.74
Numbetrs Of Electrical Heaters ( Back Up Type ) Provided 2
Collector Stand Material Mild Steel
Size Of Collector Tank Stand (L X W X H ) Must Be Greater Than 38 X38 X 4 XX XX XX mm3
System Interconnecting Pipes Material G I Pipes as per IS 1239
If Other Mention The Material For Interconnecting Pipes NA
Size Of Interconnecting Pipes 20 mm
Tank Test Pressure na bar
System Working Pressure NA Bar
Inlet And Outlet Valve Yes
Temp Gauge( For Hot Water ) Yes
Gun Metal Strainer ( For Cold Water ) Yes
Water Meter Yes
Gasket For Flanges 3 mm thick gasket of Neoprene
Electrical Back Up Control Panel Yes
Make Of Control Panel Others
If Others , Mention The Make Of Control Panel V-Guard
Weight Of Solar Water Heater System 200 kg
Availability Of Schematic Drawing Yes
Instruction Manual For Installation , Repair And Maintanance Yes
Warranty 1 Years
Availability Of Test Report As Per IS : 6893-6 (1985) Used For Purcahse Specification For Machine Tools , Part 6 Bench /Pillar Type Drill Machine With Latest Amndmt.from Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification Yes
Test Report No. NA
Test Report Date NA
Name Of The Lab NA
Address Of The Lab NA