10,000 V insulation tester With its site-proof casing, the C.A 6550 insulation tester is used to check equipment insulation during manufacturing, on-site installation work, periodic inspections and recommissioning of installations. It is ideal for electricity companies, manufacturers, installers, maintenance firms, industry, RD centres and infrastructure.Specially adapted for checking insulation on rotating machinery with a 12 kV power supply or higher, the C.A 6550 complies with the IEEE43 standard which recommends insulation testing at 5-10 kV.Functions and specificationsWide measurement range from 10 k to 25 TFixed or programmable test voltage from 40V to 10 kV5mA max. charging currentLarge backlit LCD screen with digital display, bargraph and Rtut, it and iu graphsAutomatic ratio calculation DAR / PI / DD / DR ppm/VMultiple test modes voltage ramp and step with burning, early break and I-limit modesFilters to optimize measurement stabilityCalculation.
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Inhibit test terminal voltage >30 V prior to initialization of test |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | Up to 50 Deg C Degree C |
Operating Humidity (RH) | 90% % |
Power Requirements | Battery Operated |
Type Of Battery | NiMH |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | As per data sheet |
Dimensions (H X W X L) | 406 x 330 x 174 mm mm x mm x |
Weight | 6 kg gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 01 |
Test Report Date | 01 |
Name Of The Lab | NABL |
Warranty | 1 |